Underground Conduit And Wiring - Siemens VersiCharge Ultra 50 Installation Manual

50 kw dc fast charger
Table of Contents

Advertisement

VersiCharge Ultra 50™ |
Installation Manual

Underground conduit and wiring

The Ultra 50 is supplied with a Flexa conduit system in the crate
kit, with all parts attached.
6" conduit
nipple
1. Disassemble the Flexa system
Detach all pieces of the system below the conduit. The flex
adapter is removed by pushing in the adapter ring, and pulling
out the conduit.
20
conduit
coupling
flex
adapter
Push in ring
Pull out conduit
flexa
conduit
2. Fit Flexa system into base
Install the 6" conduit nipple, conduit coupling and flex adapter
into the embedded 6" coupling (not supplied) in the
foundation, using sealant on all threads.
washer
flex
locking
adapter
ring

Advertisement