13. Relay Internal / External
The Relay must be set to "External" when using a Viking remote model RC-4A relay controller to activate external
relays. When programmed to External, the RC-4A will activate one or more of its relays for the duration of the page.
Factory Setting: Internal
14. SIP Paging Volume
The SIP Paging volume can be set from 0 - 19. 0 = lowest volume setting, 19= highest volume setting. Adjusting this
will set the volume level for SIP Paging. Factory Setting: 1
15. Ring Volume
When the Inbound Call Mode (see Programming section 22) is set to Ring, the PA-250-IP will output a loud ring when
it is called. The volume level of the loud ring can be adjusted from 0 - 19. Factory Setting: 5
16. SIP Page Length Timeout
This feature selects the maximum length of time that incoming SIP calls can be connected. Programmable in increments
of 1 minute up to a maximum of 9 minutes or disabled. With the call length disabled, the PA-250-IP must rely on a call
ended signal or touch tone # to hang-up. Factory Setting: 3 minutes
17. Multicast Page Length Timeout
The Multicast Page Length Timeout can be programmed from 1 to 255 seconds in one second increments.The Time
Out can also be disabled, allowing any length of Multicast page or continuous background music. When using standard
Multicast Paging, a timeout checkbox can be individually enabled or disabled for each multicast paging group (on the
"Codes/Paging" tab). When using Polycom Multicast Paging, the timeout checkbox enables the timeout globally on
groups 1 through 24. There is no timeout for a page to the emergency group 25. Factory Setting: 180 seconds.