A. Connect / Disconnect
Open the "Viking IP Programming" software on the PC and the start screen shown below will appear. Any Viking IP
products that are connected to the network will appear on the list. Simply select the PA-250-IP on the list and click on
the "Connect" button at the bottom or double click the selected unit. If no username and password have been
programmed and the security code of the selected unit is still set to default (845464), the PC software will not require
entering a username, password or security code to connect to the PA-250-IP. If the PA-250-IP has been programmed
with a username and password, a pop up window will ask for the username followed by the password. If the unit's
security code has been changed from "845464", it will then prompt for the correct security code. PA-250-IP's have a
default name of "VIKING_KM64_Vik02", so if many PA-250-IP's are connected to the same network and all have the
default name, MAC addresses must be used to identify each PA-250-IP. When finished programming, click on the
"Disconnect" button at the bottom. Closing the program will also automatically disconnect the unit.
B. Configuring the PA-250-IP Network Settings
Open the "Viking IP Programming" software on a windows PC that is connected to the same LAN as the PA-250-IP amplifier to be
Step 1
programmed.
The window in the upper left corner of the menu will show you each PA-250-IP that is connected to that LAN. Select the unit with the
Step 2
same MAC address shown on the label located on the top of the Ethernet connector on the PA-250-IP or the matching label that can
be found on the back panel.
Click on the "connect" button. A default PA-250-IP has no username or password programmed, the security code is set to "845464"
and when configured this way, you are instantly connected to the PA-250-IP. If the PA-250-IP has been programmed with a username
Step 3
and password, a pop up window will ask for the username followed by the password. If the unit's security code has been changed
from "845464", it will then prompt for the correct security code, then click "retry".
Step 4
The program will then read and display the PA-250-IP's IP and programming settings.
Step 5
Click on the "IP Settings" tab.
Select the appropriate value Static IP Settings or DHCP for "Set Unit IP Address via". NOTE: Changing the IP address will cause you to
Step 6
have to reconnect to the unit. Enter the values for the fields in "if DHCP fails" or "Static IP Settings" as needed.
Step 7
Set the "Unit Name", "Logging / Time Server Settings" as needed.
Select Peer-Peer in the "SIP Server / Peer to Peer Settings" to use the unit in Peer to Peer mode or for Multicast paging only. Select
Server to register with a SIP registrar server and fill in the "Outbnd Proxy" (SIP Outbound Proxy Server Address, "ip:port"), "Authentic.
Step 8
ID" (SIP Authentication ID), "Username" (SIP Username, <string>), "Password" (SIP Password), and "Caller ID" (SIP Caller ID) with
values from your VoIP provider. Required fields will be red when the unit is not registered.