LED
Link/Act
(Out-Of-Band port)
Link/Act
(10GE RJ45 ports)
Link/Act
(10GE SFP+ ports)
Link/Act
(100GE QSFP28 ports)
Stacking (Master)
(100GE QSFP28 ports)
Stacking (Slave)
(100GE QSFP28 ports)
The behavior of the LEDs during the booting or rebooting process is described per phase in the following table:
Phase
Phase 1
Phase 2
Color
Status
Amber
On (Blinking)
-
Off
Green
On (Solid)
On (Blinking)
-
Off
Green
On (Solid)
On (Blinking)
Amber
On (Solid)
On (Blinking)
-
Off
Green
On (Solid)
On (Blinking)
Amber
On (Solid)
On (Blinking)
-
Off
White
On (Solid)
(LED 1)
On (Blinking)
Blue
On (Solid)
(LED 4)
On (Blinking)
-
Off
White
On (Solid)
(LED 1)
Amber
On (Blinking)
(LED 2)
-
Off
Amber
On (Solid)
(LED 3)
Blue
On (Blinking)
(LED 4)
-
Off
LED(s)
Behavior
Locator
Lights solid blue during this phase.
Power
Remains off during this phase.
Status
Remains off during this phase.
Fan
Remains off during this phase.
Port Link/Act
Remains off during this phase.
Locator
Turns off during this phase.
Power
Turns off during this phase.
Status
Turns off during this phase.
Description
Fan error
Power off
Active connection through the port
Data transmitted and received through the port
Inactive connection, no link present, or port disabled
Active connection at 10 Gbps through the port
Data transmitted and received through the port
Active connection at 1 Gbps through the port
Data transmitted and received through the port
Inactive connection, no link present, or port disabled
Active connection at 10 Gbps through the port
Data transmitted and received through the port
Active connection at 1 Gbps through the port
Data transmitted and received through the port
Inactive connection, no link present, or port disabled
Active connection at 100 Gbps through the port
Data transmitted and received through the port
Active connection at 40 Gbps through the port
Data transmitted and received through the port
Inactive connection, no link present, or port disabled
Active connection at 100 Gbps through the port and the
Switch is the Master switch in the stack
Data transmitted and received through the port
No link present
Active connection at 100 Gbps through the port and the
Switch is a Slave switch in the stack
Data transmitted and received through the port
No link present
4