Rear Panel Components - D-Link DXS-3610 Series Hardware Installation Manual

Layer 3 stackable 10gbe managed switch
Table of Contents

Advertisement

DXS-3610 Series Layer 3 Stackable 10GbE Managed Switch Hardware Installation Guide
Phase
Phase 3
System Ready

Rear Panel Components

The rear panel features components like LED indicators, PSU (Power Supply Unit) modules, fan modules, and an
electrical grounding point. These components are described in detail below.
CAUTION: When two PSU modules are installed, they must be the same type (two ACs or two DC) and
also use the same airflow direction (back-to-front or front-to-back).
ATTENTION : Lorsque deux modules d'alimentation sont installés, ils doivent être du même type (deux
CA ou deux CC) et utiliser le même sens du flux d'air (dos à dos ou face à face).
This following table lists the rear panel components on the Switch:
Port
Switch GND
Fan Modules
Power Supply Module Slots
LED(s)
Behavior
Fan
Turns off during this phase.
Port Link/Act
Lights solid amber during this phase.
Locator
Lights solid green during this phase.
Power
Lights solid green during this phase.
Status
Blinks green during this phase.
Fan
Lights solid green during this phase.
Port Link/Act
Lights solid amber during this phase.
All
Return to normal operation behavior.
Figure 2-5 DXS-3610-54T/DXS-3610-54S Rear Panel (AC PSU)
Figure 2-6 DXS-3610-54T/DXS-3610-54S Rear Panel (DC PSU)
Description
Use an electrical grounding wire and connect one end of the wire to the switch
GND and the other end of the wire to an electrical grounding point most commonly
found on the Switch mounting rack itself.
These are five hot-swappable, redundant (4+1) fan module slots on the rear panel
of the Switch. The following fan modules can be installed in these slots:
• DXS-FAN200 (Fan module with Front-to-Back airflow)
• DXS-FAN200-B (Fan module with Back-to-Front airflow)
When five fans modules are installed, four fan modules will be active and the fifth
fan module will be passive until one of the four active fan modules fail.
There are two load-sharing power supply module slots on the rear panel of the
Switch. The following power supply modules can be installed in these slots:
• DXS-PWR700AC (AC PSU with Front-to-Back airflow)
• DXS-PWR700AC-B (AC PSU with Back-to-Front airflow)
• DXS-PWR1000DC (-48V DC PSU with Front-to-Back airflow)
5