5.1 WIRING ACTUATOR TO 936 CONTROL BOARD

8
936 CONTROL BOARD WIRING: PULL-TO-OPEN
1. Locate MOTOR 1 and MOTOR 2 connectors on 936 board per IMAGE 8-1.
1. If single gate, wire MOTOR 1 connector per IMAGE 8-2 (PULL-TO-OPEN).
2. If dual gate, wire MOTOR 1 & 2 connectors per IMAGE 8-3 (PULL-TO-OPEN)..
PULL-TO-OPEN (SINGLE GATE)
MOTOR 1
IMAGE 8-2: PULL-TO-OPEN - SINGLE
www.hysecurity.com • 800-321-9947
14
816 LA Actuator
INSTALLATION REFERENCE MANUAL
MOTOR 1
MOTOR 2
IMAGE 8-1: 936 MOTOR CONNECTOR LOCATIONS
NOTE:
If a gate moves in opposite
direction from what is expected,
reverse the motor power lead
wiring (red & black wires) for
that motor.
In dual gate systems, the
longer actuator cable is usually
conneted to MOTOR 2.
PULL-TO-OPEN (DUAL GATE)
MOTOR 1
IMAGE 8-3: PULL-TO-OPEN - DUAL
MOTOR 2
MX4684 Rev. C ©2019