Wiring Actuator To 1050 Control Board - Nice HySecurity 1500 Series Installation & Reference Manual

Vehicular swing gate actuator
Table of Contents

Advertisement

5.2 WIRING ACTUATOR TO 1050 CONTROL BOARD

10
1050 CONTROL BOARD WIRING: PULL-TO-OPEN
1. Locate MOTOR 1 and MOTOR 2 connectors on 1050 board per IMAGE 10-1.
1. If single gate, wire MOTOR 1 connector per IMAGE 10-2 (PULL-TO-OPEN).
2. If dual gate, wire MOTOR 1 & 2 connectors per IMAGE 10-3 (PULL-TO-OPEN)..
MOTOR 1
5
3
IMAGE 10-2: PULL-TO-OPEN - SINGLE
www.hysecurity.com • 800-321-9947
16
816 LA Actuator
INSTALLATION REFERENCE MANUAL
IMAGE 10-1: 1050 MOTOR CONNECTOR LOCATIONS
4
3
2
1
2
1
MOTOR
MOTOR
1
2
NOTE:
If a gate moves in opposite
direction from what is
expected, reverse the motor
power lead wiring (red &
black wires) for that motor.
In dual gate systems, the
longer actuator cable is
usually conneted to MOTOR
2.
MOTOR 1
5
4
3
2
1
3
2
1
IMAGE 10-3: PULL-TO-OPEN - DUAL
MOTOR 2
5
4
3
2
1
3
2
1
MX4684 Rev. C ©2019

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents