CHECK FOR GAS LEAKS
(CONTINUED)
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death and damage to property.
WARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
You will need: a soap and water solution and a rag or
brush to apply it.
Turn on gas supply.
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
WARNING: Do not ignite burners when leak checking.
Check:
a) Left valves to manifold connection. Figure 20 (a).
b) Center valves to manifold connection. Figure 20 (b).
c) Right valves to manifold connection. Figure 20 (c).
d) Hose to manifold connection. Figure 20 (d)
WARNING: If there is a leak at connection 20 (d)
turn OFF the gas and retighten the fitting with a
wrench and recheck for leaks with soap and water
solution.
If a leak persists after retightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact your dealer.