Description
The ESP15 is a battery operated back-up
sump pump. It does not replace a regular
pump. It is designed to provide protection
in the event household electrical power
fails.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used to
pump clear water. Fatal injury and/or
property damage could result.
If the basement has water or
moisture on the floor, do not
walk on wet area until all
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2006 Wayne Water Systems
12 Volt
Standby
Sump Pump
power is turned off. If the shutoff box is
in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
All wiring must be
performed by a
qualified electrician.
Do not expose battery to
sparks or flames as an
explosion or fire could
result.
Battery
acid is corrosive. Avoid
spilling on skin or clothing.
Eye protection must be worn
when handling the battery.
A check valve
must be used on
the primary sump pump discharge (see
Figure 1)
A ground fault
circuit interrupter is
required.
This pump must only
be used to pump
clear water. This pump is not designed to
handle effluent, salt water, brine, laundry
discharge or any other application which
may contain caustic chemicals and/or
foreign materials. Pump damage may
occur if used in these applications and
will void warranty.
Battery Requirements
1. Use only a new fully charged 12 volt
deep cycle battery. Electrolyte level
must be checked and maintained in
accordance with manufacturer's
guidelines.
2. Battery sizes that will fit into the
battery box are 24C, 24VCM, 27C,
27CM and 27F.
3. Battery recharge time will be
different at each installation. Under
normal conditions it will take two to
four days to bring a deep cycle
battery back to full charge after it has
For parts, product & service information
visit www.waynewatersystems.com
1
been discharged. If electrical power to
the house is lost more than once a
week, consider keeping a spare, fully-
charged battery to replace an
exhausted battery for the standby
sump pump.

Installation

Installation of this
unit may take
several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.
1. Turn power to main pump off.
2. Pump must be installed using 1
1
1
/
" rigid PVC piping. A check valve
2
(not included) must be installed
between the ESP's tee and the main
pump (see Figure 1).
4 inch min.
Check
valve
Figure 1
3. Measure and cut discharge pipe so
that back-up pump is a minimum of 1
inch above the main pump. This will
allow main pump to operate normally
(see Figure 1).
4. Check the fit of the components
before permanently attaching. Using
PVC cement, glue tee in place. Note
351203-001 1/06
ESP15
/
" or
1
4
1 inch
min.

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 351203-001

  • Page 1: Installation

    REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2006 Wayne Water Systems 12 Volt Standby Sump Pump power is turned off.
  • Page 2: Operation

    Operating Instructions And Parts Manual Installation (Continued) the up direction arrow on the tee; the notch must be to the top or flapper valve will not work (see Figure 2). Flapper fitting valve locator Notch Clamp Standby sump pump Figure 2 5.
  • Page 3: Troubleshooting Chart

    Operation (Continued) Red: Battery is completely discharged or defective. d. Plug in charger and main AC pump. When AC power is out, and when pump has been running, the light will indicate battery status. 4. A chirping sound from the control box will accompany the red light, indicating that the battery may require attention or replacement.
  • Page 4: Replacement Parts

    In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for such damages.
  • Page 5: Montage

    MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2006 Wayne Water Systems Pompe De Puisard De Réserve 12V avant de couper l’électricité.
  • Page 6 Instructions D’Utilisation Et Manuel De Pièces Montage (Suite) 5. Introduire la soupape à clapet dans le T. S’assurer que la languette indicatrice soit dans l’encoche du T (voir Figure 2). Languette Raccord en T indicatrice de la Encoche soupape à clapet Pompe de puisard Collier...
  • Page 7: Entretien

    Fonctionnement (Suite) batterie pourrait indiquer une condition fausse. Se référer à la section Entretien pour les instructions pour évaluer la condition de la batterie. 5. Une tonalité de trente secondes sonnera lorsque l’alimentation au système soit interrompu. Le modèle se rajustera automatiquement quand l’alimentation soit rétablit.
  • Page 8: Garantie Limitée

    Province ou d’un État à l’autre. En aucun cas, soit par suite d’un rupture de contrat de garantie, acte dommageable (y compris la négligence) ou autrement, ni Wayne ou ses fournisseurs seront responsables pour aucune dommage spéciale, incidentel ou pénal, y compris, mais pas limité...
  • Page 9: Instalación

    RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. © 2006 Wayne Water Systems Bomba Auxiliar de 12V para Sumideros sótano, no camine sobre la...
  • Page 10: Operación

    Manual de Instrucciones de Operación y Piezas Instalación (Continuación) 3. Mida y corte el tubo de descarga de modo que la bomba auxiliar esté como mínimo a 2,54cm más arriba que la bomba principal. Ésto permitirá que la bomba principal operare nor malmente (vea la Figura 1).
  • Page 11: Mantenimiento

    Operación (Continuación) Si la corriente alterna está apagada, mientras la bomba está funcionando, la luz le indicará la carga de la batería. 4. Al escuchar un sonido cuando la luz roja se enciende le indica que necesita revisar o reemplazar la batería. El voltaje sólo le indica la condición de la batería pero no le indica el estado en que se encuentra.
  • Page 12: Garantía Limitada

    Garantía Limitada Durante un año a partir de la fecha de compra, Wayne Water Systems ("Wayne") reparará o reemplazará, según lo consideren adecuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o representantes autorizados de Wayne determinen que están defectuosos debido a problemas de materiales o manufactura.

This manual is also suitable for:

Esp15

Table of Contents