Operating Instructions and Parts Manual
Description
The submersible pump is designed for
indoor home sump applications. The unit is
equipped with an 8-ft long, 3-prong
grounding type power cord. Motor is oil
filled and sealed for cooler running and
designed to operate under water. A float
switch is provided for automatic pump
operation. This pump is not suitable for
aquatic life.
General Safety
Information
Do not use to pump
flammable or explosive
fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in a
flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.
This pump is not
designed to handle
salt water, brine, laundry discharge or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.
All wiring must be
performed by a
qualified electrician. Failure to follow
this warning could result in fatal
electrical shock.
If the basement has water
or moisture on the floor,
do not walk on wet area
until all power is turned off. If the
shutoff box is in the basement, call an
electrician. Remove pump and either
repair or replace. Failure to follow this
warning could result in fatal electrical
shock.
A backup system
should be used.
Blue Angel™ offers Model BSP15 and
BSP25
© 2007 Blue Angel™ Pumps
Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.
Submersible Sump
Pump
Installation
1. Install pump in a sump pit with minimum
size as shown in Figure 1. Construct sump
pit of tile, concrete, steel or plastic.
2. The unit should be located and rest on
a solid, level foundation. Do not place
pump directly on clay, earth, gravel or
sandy surface. These surfaces contain
small stones, gravel, sand, etc. that may
clog or damage the pump and cause
pump failure.
hose is used, make sure pump is
secured in sump pit to prevent
movement. Failure to secure pump
could allow pump movement and
switch interference and prevent pump
from starting or stopping.
3. Thread check valve (Blue Angel™ offers
Model 66005-BLA1) into pump body
carefully to avoid stripping or cross
threading. Do not use pipe joint sealant.
4. Connect 1-1/2" rigid pipe to rubber boot
on check valve. Reverse boot for 1-1/4"
diameter pipe. Tighten hose clamps.
assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.
Grounded
Outlet
For parts, product & service information
visit www.blueangelpumps.com
Flood risk. If
flexible discharge
Support pump and
piping when
Min. Diameter
Tether
14"
24"
Figure 1
14"
BRSPT130
5. Protect electrical cord from sharp
objects, hot surfaces, oils, and chemicals.
Avoid kinking the cord and replace
damaged cords immediately.
IMPORTANT: Make sure there is adequate
room for the switch to operate.
6. A sump pit cover must be installed to
prevent debris from clogging or
damaging the pump or interfering with
pump.
Operation
Always disconnect the
power source before
attempting to install,
service, relocate or maintain the pump.
Never touch sump pump, pump motor,
water or discharge piping when pump
is connected to electrical power. Never
handle a pump or pump motor with
wet hands or when standing on wet or
damp surface or in water. Fatal
electrical shock could occur.
1. A ground fault circuit interrupter (GFCI)
is required.
Risk of electrical
shock! This pump is
supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.
Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.
Figure 2
350800-002 1/07

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 350800-002

  • Page 1 Use a grounded receptacle to reduce the risk of fatal electrical shock. Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable. Figure 2 350800-002 1/07...
  • Page 2: Troubleshooting Chart

    Operating Instructions And Parts Manual 2. This pump is only for use on 120 Volt (single-phase), 60 hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug. Insert the float switch cord plug directly into a 120 volt outlet.
  • Page 3: Specifications

    Specifications Power supply requirements...120V, 60 hz Motor ...Single phase, oil filled Liquid temperature range...40°F to 120°F Circuit requirements ...15 amps (min) Dimensions ...11" high x 9" base Cut-in level (factory set) ...Tether ...14" Cut-out level (factory set)...Tether ...7" For Replacement Parts, call 1-888-636-6628 Replacement Parts List •...
  • Page 4: Limited Warranty

    MUST send a copy of the purchase receipt along with the material or correspondence. Please call Blue Angel™ (888-636-6628) for return authorization and instructions. DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records. MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________ ATTACH YOUR RECEIPT HERE www.blueangelpumps.com...
  • Page 5: Installation

    3. Fileter le clapet (Wayne vous offre le Modèle 66005-WYN) dans le corps de la pompe avec soin pour éviter le foirage ou l’abattement. Ne pas utiliser le mastic de fermeture pour joints.
  • Page 6: Guide De Dépannage

    4. Remplacer l’interrupteur flotteur 5. Si la turbine ne tourne pas, enlever le carter et enlever l’obstruction 6. Assurer le movement libre du flotteur 1. Installer ou remplacer le clapet (Jeu de clapet Wayne #660005- WYN) 2. Remplacer l’interrupteur flotteur 1.
  • Page 7: Spécifications

    Spécifications Exigences d’alimentation ...120 V, 60 Hz Moteur...Monophasé,rempli d’huile Gamme de température de liquides...4,5º C à 49,3º C Exigence de circuit ...15 A (min) Dimensions ...Hauteur 27,94 cm x Base de 22,86 cm Niveau de démarrage (réglé à l’usine) ...Longe...35,56 cm Niveau d’arrêt (réglé...
  • Page 8: Garantie Limitée

    Blue Angel™ (888-636-6628) pour l’autorisation et instructions concernant le renvoi. NE PAS ENVOYER, PAR LA POSTE, CE BULLETIN À WAYNE. Utiliser ce bulletin seulement pour vos archives. Nº DU MODÈLE —————————- Nº DE SÉRIE ——————————————- DATE D’INSTALLATION ———...
  • Page 9: Instalación

    Si la bomba no se fija, el interruptor podría desconectarse con el movimiento y evitar que la bomba se encienda o se apague. 3. Atorníllele la válvula de chequeo (Wayne le ofrece el Modelo 66005-WYN) a la bomba. Cerciórese de atornillarla adecuadamente. No use pegamento (cola) en las conexiones.
  • Page 10: Guía De Diagnóstico De Averías

    Manual de instrucciones y lista de repuestos Funcionamiento (Continuación) 2. Esta bomba está diseñada para usarse en sistemas eléctricos monofásicos de 120 Volt, 60 hz, 15 amp y tiene un cordón eléctrico con 3 cables para conexión a tierra al igual que un enchufe con 3 terminales para conexión a tierra.
  • Page 11 Especificaciones Requerimientos eléctricos...120 Voltios, 60 Hz Motor ...Monofásico, con aceite Temperaturas del líquido ...4,5º C à 49,3º C Circuito eléctrico ...15 amperios (mínimo) Dimensiones ...27,94 cm alto X 22,86 cm (base ) Nivel de encendido (fijado de fábrica)...Ronzal . . .35,56 cm Nivel de interrupción (fijado de fábrica)...Ronzal .
  • Page 12: Garantía Limitada

    Comuníquese con la compañía Blue Angel™ (888-636-6628, sólo desde EE.UU) para recibir autorización e instrucciones de como enviar la mercancía. NO ENVIE ESTOS DATOS A WAYNE. Conserve esto sólo como datos. MODEL NO._______________ NO. DE SERIE __________________________ FECHA DE INSTALACION_____________...

This manual is also suitable for:

Brspt130Esp25

Table of Contents