ArcSource Outdoor 48 MC Integral Table of contents 1. Safety instructions ..............................3 2. Fixture exterior view ..............................5 3. Installation .................................. 5 3.1 Mounting the fixture ............................5 3.2 Top hat (Half top hat ) installation ........................6 3.3 Connection to the mains ............................7 4.
ArcSource Outdoor 48 MC Integral FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcSource Outdoor 48 MC Integral ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Page 4
ArcSource Outdoor 48 MC Integral When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
ArcSource Outdoor 48 MC Integral 2. Fixture exterior view 1. LED unit 2. Control unit 3. Antenna (only wireless DMX version) 4. Tilt adjusting locks 5. „U“ bracket 6. Control board with anti-vandal cover 7. Power/Data cable 8. LED unit connecting cable 3.
ArcSource Outdoor 48 MC Integral Ensure that the structure to which you are attaching the fixture is secure Caution: Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the device and consult installation with an expert.
ArcSource Outdoor 48 MC Integral 3.3 Connection to the mains Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation. This device falls under class one and must be grounded! The ArcSource Outdoor 48 MC Integral is equiped with with a 5-cored power/data cable.
Page 8
ArcSource Outdoor 48 MC Integral Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands. Note: To keep declared IP rating, every cable gland has to be covered with the end cap if this cable gland is not used for cable passing.
ArcSource Outdoor 48 MC Integral 4. Wireless DMX operation The wireless version of the ArcSource Outdoor 48 MC Integral is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band. To link the fixture with the DMX transmitter Select option “Wireless“...
ArcSource Outdoor 48 MC Integral 5. ArcSource Outdoor 48 MC Integral (RGBW) - DMX protocol Version 1.1 Mode/Channel Value Function Type of control Red LEDs 0 - 255 Red LEDs saturation control (0-100%) proportional Green LEDs 0 - 255 Green LEDs saturation control (0-100%) proportional Blue LEDs 0 - 255...
Page 11
ArcSource Outdoor 48 MC Integral 192-223 Random strobe-effects from slow to fast proportional 224-255 Shutter open step Dimmer 0 - 255 Dimmer intensity from 0% to 100% proportional Dimmer fine Proportional 0 - 255 Fine dimmer intensity from low to high...
ArcSource Outdoor 48 MC Integral 6. ArcSource Outdoor 48 MC Integral (RGBA) - DMX protocol Version 1.0 Mode/Channel Value Function Type of control Red LEDs 0 - 255 Red LEDs saturation control (0-100%) proportional Green LEDs 0 - 255 Green LEDs saturation control (0-100%) proportional Blue LEDs 0 - 255...
Page 13
ArcSource Outdoor 48 MC Integral 192-223 Random strobe-effects from slow to fast proportional 224-255 Shutter open step Dimmer 0 - 255 Dimmer intensity from 0% to 100% proportional Dimmer fine Proportional 0 - 255 Fine dimmer intensity from low to high...
ArcSource Outdoor 48 MC Integral 7. ArcSource Outdoor 48 MC Integral (SmartWhite) - DMX protocol Version 1.0 Mode/Channel Value Function Type of control Warm white LEDs 0 - 255 Warm white LEDs saturation control (0-100%) proportional Cool white LEDs 0 - 255 Cool white LEDs saturation control (0-100%) proportional Colour wheel...
ArcSource Outdoor 48 MC Integral 8. ArcSource Outdoor 48 MC Integral (Single colour) - DMX protocol Version 1.0 Mode/Channel Value Function Type of control Strobe 0-31 Shutter closed step 32-63 Shutter open step 64-95 Strobe-effect from slow to fast proportional 96-127 Shutter open step...
ArcSource Outdoor 48 MC Integral 9. Control menu map Default settings=Bold print Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 DMXA Set DMXA 0001-0512 0001 InFo POn Time. Total Reset DMX In 0-255 Dimmer F...
Page 17
ArcSource Outdoor 48 MC Integral Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 Backlight 0-100% Temp Uni °C, °F I Ef Pos 0-255 Green 0-255 Blue 0-255 White (Amber) 0-255 0-255 C Wheel 0-255...
Page 18
ArcSource Outdoor 48 MC Integral Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 Prog 3 Step 40 F.Tim. 0-25.5 sec Copy Special rdM Low rdM High LED type RGBW Sin. Col. Smart.
Page 19
Menu Level 5 Menu Level 6 Cal.Def. Sw Upd No/Yes RDM menu (e.g. for the Robe Universal Interface WTX, because this device cannot display 2-row display of the ArcSource Outdoor 48 MC Integral) Default settings=Bold print Menu Level 1 Menu Level 2...
Page 20
ArcSource Outdoor 48 MC Integral Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 M.F. ti. 0.1-25.5 tEM.u. °C, °F In.Po. GrEn bLuE WhIt C.vhE Stro dimr F.dim SAVE dF. SE. Man.
Page 21
ArcSource Outdoor 48 MC Integral Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 PrG3 St. 40 S.tim. 0-25.5 F.tim. 0-25.5 COPy SPEC rdM. L. rdM. H. t. LEd rGbV Si. Co. SM.
ArcSource Outdoor 48 MC Integral Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 5600 8000 CA.dF. no/yES 10. Fixture menu The control panel menu allows to set the fixture according to your needs, obtain information on its operation and manual control of all effects.
ArcSource Outdoor 48 MC Integral In order to reset this counter to 0 you have to press and hold the UP and DOWN buttons and at the at the same time press the ENTER button. DM In ---DMX values. Select this function to read DMX values of each channel received by the fixture. Temp ---Fixture Temperatures.
ArcSource Outdoor 48 MC Integral M FTime --- Max. Fade time. Select this menu item to set a desired max. fade time (0-25.5 sec.). This adjusted fade time influences fade of R,G,B,W and dimmer during DMX operation: If time between two receiving DMX values is > than fade time set in the item “M Ftime“, the entire adjusted fade time will be used.
ArcSource Outdoor 48 MC Integral 10.6 Stand-alone setting The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture. Auto Run --- Automatic playback. This function allows you to select the program which will be played after switching the fixture on.
ArcSource Outdoor 48 MC Integral 7. Use the UP/DOWN buttons to select next channel and press the ENTER button. 8. After having set all channels in the current program step, press the MODE button to go by one menu level back and select another program step.
Page 27
If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface via a DMX cable.
ArcSource Outdoor 48 MC Integral 6. Select correct "COM " number if you use a Flash cable RS232/DMX or select " Robe Universal Interface " if you use the Robe Universal Interface/Robe Universal Interface WTX and then click on the "Connect" button.
Page 29
ArcSource Outdoor 48 MC Integral MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIPTION DEVICE_HOURS Please, see the Robe Universal Interface user manual for detail description of RDM operation.
ArcSource Outdoor 48 MC Integral 12. Technical specifications Power supply • Electronic auto-ranging • Input voltage (US): 100 - 277V AC, 50-60 Hz • Max power consumption: 130W (power factor=0.93) Optic & Effects • Light source: 12 x high power multi-chip LEDs •...
Page 31
ArcSource Outdoor 48 MC Integral Dimensions (mm) ArcSource Outdoor 48 MC Integral Junction box...
Page 32
ArcSource Outdoor 48 MC Integral Top hat Half top hat Tilt adjustment range • -35°/+90° Weight • 10.8 kg (23.8 lbs) Protection factor US: Suitable for wet location Impact resistance • IK 10 Connection • Data/power cable: Li9Y11Y 3xAWG16+2xAVG24 shielded and jacketed •...
Maintenance and service operations ( including replacement of the fuse) have to be realized by a qualified person.. Should you need any spare parts, please use genuine parts. Specifications are subject to change without notice. May 24, 2022 Made in ROBE Lighting s.r.o., Palackého 416, 757 01 Valašské Meziříčí, Czech Republic...
This manual is also suitable for:
Anolis arcsource outdoor 48 mc integral rgbaAnolis arcsource outdoor 48 mc integral smartwhiteAnolis arcsource outdoor 48 mc integral singlecolour
Need help?
Do you have a question about the Anolis ArcSource Outdoor 48 MC Integral RGBW and is the answer not in the manual?
Questions and answers