A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
8 in.
(203 mm)
12-5/8 IN.
(321 mm)
12-5/8 IN.
(321 mm)
ROOF DECK INSULATION SHIELD
Figure 12.2 SLP Series Vent Components
Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20
72
8 in.
(203 mm)
*5 in.
(127 mm)
SLP-TRAP
Horizontal Termination Cap
3-13/16 in.
(97 mm)
SL-2DVP
Adapter
20 IN.
(508 mm)
10-5/8 IN.
(270 mm)
SLP-RDS
Heat
Shield
Max
Effective
Length
3-15/16 in.
(101 mm)
5-1/16 in.
(128 mm)
14-7/16 in.
* Center of the horizontal vent pipe to
the vertical measuring surface.
Minimum
Term Cap
Effective Length
3-1/8 in.
Trap1
79 mm
5-1/4 in.
Trap2
133 mm
14-7/16 in.
367 mm
367 mm
SLP-WT-BK
Wall Thimble-Black
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
Maximum
Effective Length
4-3/4 in.
121 mm
9-1/4 in.
235 mm
2-5/16 in.
59 mm