1 1
Product Specifi c and Important Safety Information
A. Appliance Certifi cation
MODELS: COSMO42-IFT-B, COSMO36-IFT-B,
COSMO32-IFT-B
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2017 • CSA 2.33-2017
This product is listed to ANSI standards for "Vented
Gas Fireplace Heaters" and applicable sections of "Gas
Burning Heating Appliances for Manufactured Homes
and Recreational Vehicles", and "Gas Fired Appliances
for Use at High Altitudes". Also Certifi ed for Installation in
a Bedroom or a Bedsitting Room.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as defi ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certifi ed to the re-
quirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certifi cation Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 "Certifi cation and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20
4
C. BTU Specifi cations
Models
(U.S. or Canada)
COSMO42-IFT-B
(0-2000 FT)
(NG)
COSMO42-IFT-B
(0-2000 FT)
(PROPANE)
COSMO36-IFT-B
(0-2000 FT)
(NG)
COSMO36-IFT-B
(0-2000 FT)
(PROPANE)
COSMO32-IFT-B
(0-2000 FT)
(NG)
COSMO32-IFT-B
(0-2000 FT)
(PROPANE)
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certifi ed without a
reduction of input rate for elevations up to 4500 feet
(1370 m) above sea level. Please consult provincial and/
or local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orifi ce size.
Orifi ce
Maximum
Minimum
Size
Input BTU/h
Input BTU/h
(DMS)
25,250
17,500
#42
23,500
17,500
.057
20,500
14,500
#44
19,000
14,000
#55
19,000
13,250
#45
1.25
16,500
12,750
mm