• Switch
S2 (C1)
: RESET switch
Used to re-start the system forcibly by means of
hardware.
The setting values of FARAD systm can be undefined
values when the RESET switch is press while the
FARAD system is operating. Do not press the RESET
switch especially while the hard disk is being accessed.
S3 (E3)
: SW1 switch
Sets operation of CPU-1 (A/V).
The switches from S3-1 through S3-8 are all set to OFF
during normal operation and have been set to OFF when
shipped from the factory. Application software may not
operate when these switches are not set to all OFF.
S3
ON
1
2
3
4
5
Switch
FunctionSwitch ON
S3-1
Bootstrap
OFF : From flash memory (in use)
ON : From ROM (in use)
S3-2
Flash memory object select bit 1
This switch is set to OFF during normal operation
S3-3
Flash memory object select bit 2
This switch is set to OFF during normal operation
S3-4
ROM object select bit 1
This switch is set to OFF during normal operation
S3-5
ROM object select bit 2
This switch is set to OFF during normal operation
S3-6
Serial baud rate
ON : 9600 bps
OFF : 38400 bps
S3-7
Reserved
(Default)
S3-8
Reserved
(Default)
m
*1 An object can be specified when booting from the
flash memory. However, set the switches S3-2 and
S3-3 to OFF during normal operation and have been
set to OFF when shipped from the factory.
*2 Refer to section "5-3. PROGRAM INSTALLATION
PROCEDURE".
*3 The serial baud rate sets the communication speed of
the RS-232C connectors (CN4, CN300) on the front
panel side of the CPU-253 board.
FDDR-7000 IM
6
7
8
*3
3-1. Description of On-Board Switch Settings and LEDs
To execute the CPU-253 board diagnostics function, set
the switches S3 and S301 as follows. Be careful that the
communication speed for the CPU-253 board diagnostics
function is fixed to 9600 bps regardless of the baud rate
setting of switches S3-6 and S301-6.
S3
ON
1
2
3
CPU-253 board diagnostics setting
S301 (K2)
: SW2 switch
Sets operation of CPU-2 (FARAD).
These switches are all set to OFF during normal operation
and have been set to OFF when shipped from the factory.
Application software may not operate when these switches
are not set to all OFF.
S302 (L2)
: SW3 switch
Used for factory adjustment. These switches are all set to
OFF during normal operation and have been set to OFF
when shipped from the factory.
S301, S302
ON
1
2
3
*1
*1
*2
*2
4
5
6
7
8
4
5
6
7
8
3-3(E)