Power Sources Technical Specifications - Lincoln Electric SAF-FRO DIGISTEEL III 320C Safety Instructions For Operation And Maintenance

Table of Contents

Advertisement

1.3. POWER SOURCES TECHNICAL SPECIFICATIONS

Primary side
Primary power supply
Primary power supply frequency
Effective primary consumption
Maximum primary consumption
Fuse primary
Maximum apparent power
Maximum active power
Recommended power generator
Active power in standby (IDLE)
Efficiency at maximum current
Power factor at maximum current
Cos Phi
Secondary side
No load voltage (according standard)
Welding range Max MIG
Welding range Max MMA
Duty cycle at 100% (10 min cycle at 40°C)
Duty cycle at 60% (6 min cycle at 40°C)
Duty cycle at maximum current at 40°C
Wire feeder
Rollers plate
Wire feeding speed
Wire diameter usable
Weight, type, size of wire spool
Maximum pressure of gas
Miscelleanous
Dimensions (Lxwxh)
Weight
Operating temperature
Storage temperature
Torch connection
Protection index
Insulation class
Standard
WARNING: This power source cannot be used in falling rain or snow. It may be stored outside, but it is not designed for use
without protection during raining.
DIGISTEEL III 320C / DIGIPULS III 320C
DIGISTEEL III 320C - W000385049
400V +/- 20%
50/60Hz
12 A
18,7 A
20 A Gg
13,1 KVA
12,1 KW
20 KVA
50 W
0,87
0,92
0,99
74 V
10V / 50V
15A / 320A
220A
280A
320A
0,5 – 25,0 m / mn
755 x 300 x 523 mm
"European type"
60974-1 & 60974-5 & 60974-10
DIGIPULS III 320C - W000402089
400V +/- 20%
50/60Hz
12 A
18,7 A
20 A Gg
13,1 KVA
12,1 KW
20 KVA
50 W
0,87
0,92
0,99
74 V
10V / 50V
15A / 320A
220A
280A
320A
4 rollers
0.6 to 1,2 mm
300 mm
6 bar
28 Kg
- 10°C/+40°C
- 20°C/+55°C
IP 23
H
EN
5 / 28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saf-fro digipuls iii 320cW000385049W000402089

Table of Contents