Lincoln Electric SAF-FRO DIGISTEEL III 320C Safety Instructions For Operation And Maintenance page 10

Table of Contents

Advertisement

Left
Right display
display
On -;OFF – Aut
GrE
Nnc – no - OFF
ScU
OFF– 0,01 – 1,00
CPt
Nno – yES
PGM
OFF – ;000 – 020 %
PGA
Nno – yES
rC
OFF – on
CAL
0 – 50
L
0 – 50
r
Nno – yES
SoF
Nno – yES
FAC
Left
Right display
display
00.5 – 10.0
tPt
00.0 – 10.0
PrG
OFF – 00.1 – 10.0
tHS
-- 70 – 70
IHS
-- 70 – 70
UHS
OFF – 00.1 – 05.0
dSt
-- 70 – 00.0
DdSI
-- 70 – 70
dSU
0.00 – 0.20
Pr_
Nno – yES
PrS
00.0 – 10.0
PoG
--10 – 10
dYn
--20 – 20
--10 – 10
rFP
--20 – 20
00 – 100
dyA
OFF – 0.01 – 2.50
tSE
---50 – 50
ISE
3.3.4. Program management
DIGISTEEL III 320C / DIGIPULS III 320C allows creating, store and modifying up to 99 welding programs directly on front panel from
program 00 to program 99. This function is activated by moving parameter PGM from no to YES in COnFIG menu.
P00 is the working program in any state. (Program management mode activated or desactivated). When power source is working on
this program, the Led indicator "JOB" is switched off. All commutators are accessible in this mode, so it will be used to set programs.
P01 to P99 are program saved, only if program management mode is activated. When power source is working on these programs,
the led indicator "JOB" is switched on. In this mode, commutators welding process, wire diameter, gas and metal are not available.
When a program selected has been modified, the indicator "JOB" blinks.
Create and save a program:
10 / 28
Step
Default
Configuration of the Water Cooling Unit. 3 possibles states :
-
Aut
-
-
Security of water cooling. 3 possible states :
-
OFF
-
-
Trigger holding time in order to call program (Only in 4T welding mode).
0,01 s
0,30
Can be use only for welding program from 50 to 99.
Activate / desactivate program management mode
no
Use to setup available adjustement range of the following parameters: wire speed, arc
1 %
voltage, arc dynamics, pulse fine-setting. Use only when program management is
OFF
activated and programs are locked.
This parameter activates / desactivates remote control or potentiometer torch when plug
no
on power source.
Calibration of torch & ground harness
OFF
1 uH
Cable choke setting / display
14
1 W
Cable resistor setting / display
8
Software update mode.
no
Factory settings reset. Pressing YeS will cause a reset of the parameters to factory
no
defaults when exit SETUP menu.
List of accessible parameters in CYCLE menu
Step
Default
Spot time. In Spot mode and in Manual mode, the Hot Start, Downslope and sequencer
0,1 s
0,5
settings cannot be changed
0,1 s
Pre-gas time
0,5
0,1 s
Hot start time
0,1
1 %
Hot start current (wire speed). X% ± the welding current
30
1 %
Hot start voltage X% ± the arc voltage
0
0,1 s
Down-slope time
OFF
1 %
-- 30
Down-slope current (wire speed). X% ± the welding current
Down-slope voltage. X% ± the arc voltage
1 %
0
0,01 s
Anti-stick time
0,05
Pr-Spray activation
no
0,05 s
Post-gas time
0,05
1 %
Fine setting in short arc
0
1 %
Fine setting in pulse
0
Arc striking dynamics at electrode
1
50
0,01 s
Sequencer time (Sequencer, only in synergic mode)
OFF
Sequencer current level. X% ± the welding current
1 %
30
Description
On : Forced on, watercooler is always activated
OFF : Forced off, watercooler is always desactivated
Aut : Automatic mode, Watercooler works when according need
nc : Normally closed,
no : Normally open,
OFF : Desactivate
Description
DIGISTEEL III 320C / DIGIPULS III 320C
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saf-fro digipuls iii 320cW000385049W000402089

Table of Contents