Power Wave 405 Technical Specifications - Lincoln Electric power wave 405 Operator's Manual

Hide thumbs Also See for power wave 405:
Table of Contents

Advertisement

Available languages

Available languages

because of electromagnetic disturbances. Consider the following.
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
Radio and/or television transmitters and receivers.
Computers or computer controlled equipment.
Safety and control equipment for industrial processes.
Personal medical devices like pacemakers and hearing aids.
Equipment for calibration and measurement.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be
sure that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities
that are taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary
to take additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together.
If possible connect the work piece to ground in order to reduce the electromagnetic emissions. The operator
must check that connecting the work piece to ground does not cause problems or unsafe operating
conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Power Wave 405 Technical specifications

Input Voltage
200-220 / 380-400 / 415 V
1/3 phase
Duty Cycle (EN60974-1)
(Based on a 10 min. period)
35%
60%
100%
Welding Current Range
5A to 425A
Heigth
373 mm
Operating Temperature
–20°C to +40°C
For any maintenance or repair operations it is recommended to contact the nearest Lincoln technical service
center. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
INPUT
Input Power at Rated Output
10,8kW @ 60% FM (3phase)
20kW @ 60% FM (1phase)
RATED OUTPUT
Output Current
400A (3phases) / 380A (1phase)
350A (3 phases) / 320A (1 phase)
300A (3 phases) / 275A (1 phase)
OUTPUT RANGE
Open Circuit Voltage
70V
DIMENSIONS
Width
318 mm
Frequency
50/60 Hertz (Hz)
Output Voltage
36V (3ph) / 35V (1ph)
34V (3ph) / 33V (1ph)
32V (3ph) / 31V (1ph)
Auxiliary Power
40V DC (wire feeder)
230V AC (water cooler)
Length
706 mm
Storage Temperature
-25°C to +55°C
Weight
37.4 Kg