4.7
PARAMETERS FOR FILLING IN THE PACKAGE
FICHE.
In case you should wish to install an assembly, starting from the
Victrix Tera (28, 32 or 38) boiler, use the assembly charts in Fig.
60 and 63.
To complete it properly, fill the relevant spaces (as shown in the
assembly sheet facsimile Fig. 58 and 61) with the values shown
in tables (Fig.  59 and 62.
Facsimile for filling in the package fiche for room central heating systems.
Seasonal central heating energy efficiency of the boiler
Temperature control
From temperature
control board
Supplementary boiler
From boiler board
Solar contribution
From the board of the solar device
Dimensions of the
( 'III' x
Supplementary heat pump
From the heat pump
board
Solar contribution and supplementary heat pump
Select the lowest
value
Seasonal central heating energy efficiency of the set
Seasonal central heating energy efficiency class of the set
Boiler and supplementary heat pump installed with low temperature heat emitters
at 35 °C?
FFrom the board of the heat
pump
The energy efficiency of the set of products indicated in this sheet may not reflect the actual energy
efficiency after installation since such efficiency is affected by additional factors, such as the heat loss
in the distribution system and the size of the products compared to the size and features of the building.
62
Class I = 1 %, Class II = 2 %,
Class III = 1.5 %, Class IV = 2 %,
Class V = 3 %, Class VI = 4 %,
Class VII = 3.5 %, Class VIII = 5 %
Volume of the
manifold (in m
)
tank (in m
)
2
3
+ 'IV' x
0.5 x
G
F
E
< 30 % ≥ 30 % ≥ 34 % ≥ 36 % ≥ 75 % ≥ 82 % ≥ 90 % ≥ 98 % ≥ 125 %≥ 150 %
The remaining values must be obtained from the technical data
sheets of the products used to make up the assembly (e.g. solar
devices, integration heat pumps, temperature controllers).
Use board Fig. 60 for "assemblies" related to the central heating
mode (e.g.: boiler + temperature controller).
Use board Fig. 63 for "assemblies" related to the domestic hot
water function (e.g.: boiler + solar thermal system).
Seasonal central heating energy efficiency of the room
(%)
(
- 'I'
) x 0.1
Classification of the
tank
A* = 0.95, A = 0.91,
Efficiency of the
B = 0.86, C = 0.83,
manifold (in %)
D-G = 0.81
) x (0.9 x (
/ 100) x
Seasonal central heating energy efficiency of the
room (%)
(
- 'I' ) x 'II'
4
5
O
0.5 x
D
C
B
A
7
+
( 50
x
1
%
'I'
2
+
%
3
±
%
=
4
+
%
=
5
+
%
=
6
-
%
=
7
%
A
A
A
+
++
+++
%
'II'
)
=
58