Victrix Tera 28 1
Id
Parameter
Parameter
DHW minimum no. of
S0
fan revs
DHW maximum no.
S1
of fan revs
Fan speed
S2
Ignition phase
Victrix Tera 32 1
Id
Parameter
Parameter
DHW minimum no.
S0
of fan revs
DHW maximum no.
S1
of fan revs
Fan speed
S2
Ignition phase
Victrix Tera 38 1
Id
Parameter
Parameter
DHW minimum no.
S0
of fan revs
DHW maximum no.
S1
of fan revs
Fan speed
S2
Ignition phase
Description
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition phase
Description
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition phase
Description
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition phase
Range
Default
20 - 60
27 (G20)
(x 50 =RPM)
26 (G31)
S0 - 140
121 (G20)
(x 50 =RPM)
115 (G31)
40 - 80
56 (G20)
(x 50 =RPM)
56 (G31)
Range
Default
20 - 60
28 (G20)
(x 50 =RPM)
28 (G31)
S0 - 140
128 (G20)
(x 50 =RPM)
121 (G31)
40 - 80
56 (G20)
(x 50 =RPM)
56 (G31)
Range
Default
20 - 60
27 (G20)
(x 50 =RPM)
28 (G31)
S0 - 140
122 (G20)
(x 50 =RPM)
122 (G31)
40 - 80
56 (G20)
(x 50 =RPM)
56 (G31)
Cus-
tomised
value
Cus-
tomised
value
Cus-
tomised
value
49