Immergas Victrix Tera 28 1 Instructions And Warnings page 47

Hide thumbs Also See for Victrix Tera 28 1:
Table of Contents

Advertisement

Id
Parameter
Parameter
Max DHW
P0
output
P1
Min CH output Defines in percentage the minimum output in central heating mode
P2
Max CH output
P3
-
Pump
P4
functioning
External probe
P5
correction
P6
-
P7
-
Id
Parameter
Parameter
Central heating set
t0
point minimum
temperature
Central heating set
t1
point maximum
temperature
t2
Solar delay timing
Domestic hot
t3
water priority
timing
Central heating
t4
ignitions timer
Central heating
t5
ramp timer
Description
Defines the maximum heat output percentage of the boiler during
the D.H.W. phase compared to the maximum heat output available
Defines the maximum heat output percentage of the boiler during the
central heating mode compared to the maximum heat output available
Not available for this model
The pump can function in two ways.
- 0 intermittent: in winter "mode" the circulator is managed by the
room thermostat or by the remote control
- 1 continuous: in "winter" mode the circulator is always powered and
is therefore always in operation
If the reading of the external probe is not correct it is possible to correct
it in order to compensate any environmental factors.
Not available for this model
Not available for this model
Description
Defines the minimum flow temperature.
Defines the maximum flow temperature.
The boiler is set to switch-on immediately after a request for DHW.
In the case of coupling with a solar storage tank positioned upstream
from the boiler, it is possible to compensate the distance between the
storage tank and the boiler in order to allow the water to reach the
boiler. Set the time necessary to verify that the water is hot enough
(see par. Solar panels coupling)
In winter mode the boiler, at the end of a domestic hot water request,
is ready to switch to central heating mode if there is an active request.
Timing sets a time period in which the boiler waits before changing
the operating mode, in order to quickly and comfortably satisfy an
additional request for domestic hot water.
The boiler has an electronic timer, which prevents the burner from
igniting too often in central heating mode
In central heating mode, the boiler performs an ignition ramp in order
to reach the maximum output set
Range
Default
0 - 100 %
100 %
0 - P2
0 %
Victrix Tera 28 1
G20 = 85
G31 = 82
Victrix Tera 32 1
0 - 100 %
G20 = 85
G31 = 85
Victrix Tera 38 1
G20 = 80
G31 = 81
-
-
0 - 1
0
-9 - 9 K
0
-
-
-
-
Range
Default
20 - 50 °C
25
(t0+5) - 85 °C
85
0 - 30 seconds
2
0 - 100 seconds
2
(step 10 sec)
0 - 600 seconds
18
(step 10 sec)
0 = 840 seconds
18
(step 10 sec)
Custom-
ised value
Cus-
tomised
value
47