Horizontal intake-exhaust kit Ø 60/100. Kit assembly (Fig. 18).
Install the bend with flange (2) on the central hole of the boiler,
positioning gasket (1) with the circular projections downwards in
contact with the boiler flange, and tighten using the screws present
in the kit. Fit the Ø 60/100 (3) concentric terminal pipe with the
male side (smooth) to the female side of the bend (2) up to the
end stop; making sure that the internal and external wall sealing
plate have been fitted, this will ensure sealing and joining of the
elements making up the kit.
• Extensions for Ø 60/100 horizontal kit (Fig. 19).
The kit with this configuration can be extended up to a max.
horizontal length of 12.9 m including the terminal with grid and
excluding the concentric bend leaving the boiler. This configu-
ration corresponds to a resistance factor of 100. In this case the
special extensions must be requested.
Immergas also provides a Ø 60/100 simplified terminal, which in
combination with its extension kits allows you to reach a maxi-
mum extension of 11.9 metres.
Horizontal intake-exhaust kit Ø 80/125. Kit assembly (Fig. 20).
To install the kit Ø 80/125 one must use the flanged adapter kit
in order to install the flue system Ø 80/125. Install the flanged
adaptor (2) on the central hole of the boiler, positioning gasket
(1) with the circular projections downwards in contact with the
boiler flange, and tighten using the screws contained in the kit.
Engage the bend (3) with the male side (smooth) to the end stop
on the adapter (1). Fit the Ø 80/125 (5) concentric terminal pipe
with the male side (smooth) to the female side of the bend (4)
(with lip seals) up to the end stop; making sure that the internal
(6) and external wall sealing plate (7) have been fitted, this will
ensure sealing and joining of the elements making up the kit.
2
1
The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Int./exhaust concentric terminal Ø 60/100 (3)
N° 1 - Internal wall sealing plate (4)
N° 1 - External wall sealing plate (5)
3
4
2
1
The adaptor kit includes:
N° 1 - Gasket (1)
N° 1 - Adapter
Ø 80/125 (2)
3
4
5
5
6
The Kit Ø 80/125 includes:
N° 1 - Ø 80/125 87° concentric bend (3)
N° 1 - Int./exhaust concentric
terminal Ø 80/125 (4)
N° 1 - Internal wall sealing plate (5)
N° 1 - External wall sealing plate (6)
The remaining kit components must
not be used
• Extensions for Ø 80/125 horizontal kit (Fig. 21).
The kit with this configuration can be extended up to a max.
length of 32 m, including the terminal with grid and excluding the
concentric bend leaving the boiler. If additional components are
assembled, the length equivalent to the maximum allowed must be
subtracted. In this case the special extensions must be requested.

1.17 CONCENTRIC VERTICAL KIT INSTALLATION.

• Type C configuration, sealed chamber and fan assisted.
Concentric vertical intake and exhaust kit. This vertical terminal
is connected directly to the outside of the building for air intake
and flue exhaust.
N.B.: the vertical kit with aluminium tile enables installation on
terraces and roofs with a maximum slope of 45% (approx 25°) and
the height between the terminal cap and half-shell (374 mm for
Ø 60/100 and 260 mm for Ø 80/125) must always be observed.
C
13
18
C
13
20
Max. 12900 mm
Max. 12790 mm
Max. 32000 mm
Max. 31956 mm
C
13
19
C
13
21
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix tera 32 1Victrix tera 38 1

Table of Contents