Using The Boiler - Immergas Victrix Tera 28 1 Instructions And Warnings

Hide thumbs Also See for Victrix Tera 28 1:
Table of Contents

Advertisement

2.4

USING THE BOILER.

Before ignition make sure the heating system is filled with water
and that the manometer (8) indicates a pressure of 1 - 1.2 bar.
- Open the gas cock upstream from the boiler.
- Press the button "
"stand-by" ( ) to "summer" (
• Summer (
): in this mode the boiler functions only to produce
the DHW, the temperature is set via the buttons "
relative temperature is shown on the display via the indicator
(19). Moreover, the temperature level that can be selected is
shown on the indicator (22).
• Winter (
): in this mode the boiler works both for producing
domestic hot water and for central heating. The DHW tem-
perature is always regulated via the buttons "
heating temperature is regulated via the buttons "
relative temperature is shown on the display via the indicator
(19). Moreover, the temperature level that can be selected is
shown on the indicator (15).
From this moment the boiler functions automatically. With no
demand for heat (central heating or domestic hot water pro-
duction) the boiler goes to "standby" function, equivalent to
the boiler being powered without presence of flame. Each time
the burner ignites, the relative flame present symbol is displayed
(11) with relative output scale.
• Operation with Comando Amico Remoto
al). If the CAR
is connected, the (
V2
the display. The boiler regulation parameters can be set via the
CAR
control panel and the reset button (3) remains active on
V2
the boiler control panel, along with the switch-off button (1)
("off " mode only) and the display where the functioning state
is shown.
N.B.: if the boiler is put into "off " mode, the "ERR>CM" con-
nection error symbol will appear on the CAR
however powered constantly so as not to lose memorised pro-
grams.
• Solar operating mode (
ically id the boiler detects a probe on the DHW inlet (optional)
or if the "Solar ignition delay" parameter is more than 0 seconds.
" repeatedly to cyclically switch from
) and "winter" (
", the central
(CAR
V2
V2
) symbol will appear on
. The CAR
V2
). This function is activated automat-
During a withdrawal, if the outlet water is hot enough or if there
is "Solar ignition delay" time, the boiler does not switch on, the
D.H.W. withdrawal symbol (
with the flashing solar function symbol (
When the water supplied by the solar system is at a temperature
lower than what is set, or if the "Solar ignition delay" time has
) mode.
elapsed, the boiler switches on. At this point, the solar function
symbol remains permanently on.
" and the
• Operation with optional external probe (
system with optional external probe, the boiler flow temperature
for central heating is managed by the external probe depending
on the external temperature measured (Par. 1.11). The flow tem-
perature can be modified by selecting the functioning curve via
the buttons "
to the boiler) selecting a value from "0 to 9".
" and the
With external probe present, the relative symbol (12) will appear
on the display. In the central heating mode, if the temperature
of the water contained in the system is sufficient to heat the
radiators, the boiler can only function with the activation of the
pump.
• "Stand-by" mode. Press button "
symbol (
though the antifreeze, pump anti-block and 3-way function and
signalling of any anomalies are guaranteed.
• "Off " mode. By holding the button "
) (Option-
onds, the display switches-off and the boiler is off completely.
The safety functions are not guaranteed in this mode.
ATTENTION:
in "Stand-by" and "Off " mode, the boil-
er is to be considered still live.
• Display operation. The display lights up while the control panel
is
V2
is being used; after a set inactivity period, the brightness drops
until only the active symbols are displayed. The lighting mode can
be varied via parameter "t8" in the P.C.B. programming menu.
) appears on the display along
" (or on the CAR
control panel, if connected
V2
) appears. The boiler remains off from this moment,
).
). In the case of a
" repeatedly until the
" down for 8 sec-
35