<parameter explanation>
Item between [ and ] means optional but at least one should be checking condition.
"Digital input number":
"Digital input state":
"operator":
{"hour":"minute":"second"}:
"M":
"Digital output number":
"Digital output state":
<example>
{17:30:00}+M=1H will set NC of SW1 to short with COMMON after 17:30 or any motion is detected.
1H*2\+{8:30:00}=1L will set NO of SW1 to short with COMMON after 8:30 or DI1 high companied
with DI2 transient from high to low.
Note that "Upload snapshot while I/O script matched" should be checked in advance to enable
function.
1 ~ 4
H (high), L (low), / (low to high), \ (high to low)
+ (OR), * (AND)
set a time alarm repeats everyday. "hour" set to 24 will check
"minute":"second" every hour. "minute" set to 60 will check "second"
every minute.
motion detection event. Note that "Upload snapshot while motion
detected" should be set in advance.
1 ~ 2
H (NC), L (NO)
57
www.vivotek.com
T: 886-2-22404099
F: 886-2-22404097