Summary of Contents for Assa Abloy Yale Real Living YRL210
Page 1
Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalecommercial.com. Cliquez sur le " ; Information sur le produit et Documentation" et puis " Installation Instructions". P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
(reverse). IMPORTANT: Latch bevel must match door bevel and plunger of deadlocking latch must stop on strike plate when door is closed. Strike plate Plunger P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 6
Figure A Exterior Escutcheon (with gasket) Do not remove clip from Exterior Escutcheon shank until correct handing has been determined and Exterior Lever Handle is to be installed. (See pages 10-11) P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 7
5. Remove the battery cover from the back of the interior escutcheon (Fig. 8) by loosening the captive Phillips head screw, then lifting the cover up and out. Note tabs at bottom of cover. Figure 8 P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 8
Interior of Door Do not over-tighten. Figure 10 8. Finish routing the wire harness and connector through the left upper slot, then behind center rib (Fig. 11). Interior of Door Figure 11 P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 9
(see Fig. 14). Thumbturn must be in vertical position. NOTE: Verify that wire harness is not being pinched or damaged while installing mounting screws. Thumbturn in vertical position Figure 14 P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 10
11 of the installation and programming manual. Next, perform the operation tests defined in step 20 on page 13 of the installation and programming manual. Failure to install and test the cylinder for proper function may result in improper lock operation. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 11
Figure 17. Figure 17 B. Insert key in cylinder. While supporting cylinder tailpiece (with finger) rotate key 90° clockwise (CW) to vertical position regardless of lever handing. Figure 18 See Figure 18. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 12
If operation is not smooth for these procedures, review the previous steps to ensure proper installation, while maintaining proper alignment of escutcheons. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 13
Install Batteries 21. Insert four (4) AA alkaline batteries; the lock will respond with flashes and beeps. 22. Install battery cover and tighten Phillips head screw. Figure 24 P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Enter User PIN. Can be 4-8 digits in length. Press the key on the keypad to Accept entry. Pound User Number (1 - 25); Press the key on the keypad to enter RF Controlled (1 - 250). Menu mode. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 15
PIN code the unit will shut down and not allow operation. Default setting is (5). Limit is adjust- able* from one (1) to ten (10) times. *Adjustable only when using Network Module with compatible integrated controller P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Note: When registering User codes, the code must be entered within 20 seconds. If time expires, no codes are registered and the process must be re-started. Protect your privacy; always shield your PIN code entry. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 17
**5 Times Shutdown Time **60 Seconds *The Master PIN code must be registered prior to any other programming of the lock **Adjustable only when using Network Module with a compatible itegrated controller P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 18
(PC or hand-held **This function appears device) to ensure communication between the lock Delete only with RF network and the controller unit. module installed. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Page 19
Open Door with PIN Code Enter PIN code. Complete the code entry Unlock. by pressing the key. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
Verify proper door preparation and re-bore holes that are too small or misaligned. d. Verify keypad wire harness is routed under the latch (see Fig. A). e. Verify latch is installed with correct side up (Fig. A). Interior of Door Figure A P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface; it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST). ** Network module units only P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
C. Push handle in allowing holes for set screw to align. D. Insert set screw and tighten by turning set screw counter-clockwise. E. Verify that new cylinder fits and rotates freely. F. Test operation of the new cylinder/key. P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...
User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ P/N AYRT-210-INST-FUL Rev E An ASSA ABLOY Group brand...