Before you begin
Smart Module
DOWNLOAD
(Optional)
THE BILT APP
for step-by-step installation
instructions & to register
your product
Retrofitting or modifying this product may impact fire rating, safety features and warranty.
Consult with code specifications to ensure compliance with all codes and ratings.
1
P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A

Advertisement

loading

Summary of Contents for Assa Abloy Yale Real Living Assure Lock YRC256

  • Page 1 Yale Assure Lock ® ® Interconnected Key Free Touchscreen ® Installation and Programming Instructions (YRC256) Inside Outside of Door of Door 4" Shown - 5.5" Available Before you begin Smart Module DOWNLOAD (Optional) THE BILT APP for step-by-step installation instructions & to register your product Retrofitting or modifying this product may impact fire rating, safety features and warranty.
  • Page 2: Before You Begin

    2-1/8" (54mm) www.yalelocks.com 1-3/4" (45mm) Yale® is a registered trademark of Y ale 2-3/8" (60mm) Security Inc., an ASSA ABLOY Group Door Thickness company. Copyright © 2016, Yale Security Inc., an ASSA ABLOY Group Recommended Centerline company. 36" (91 cm) From Floor.
  • Page 3 1-3/4" (45mm) 2-3/8" (60mm) Yale® is a registered trademark of Yale Door Thickness Security Inc., an ASSA ABLOY Group company. Copyright © 2016, Yale Security Inc., an ASSA ABLOY Group Recommended Centerline company. 36" (91 cm) From Floor. All rights reserved. Reproduction in...
  • Page 4 2-1/8" (54mm) www.yalelocks.com 1-3/4" (45mm) 2-3/8" (60mm) Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group Door Thickness company. Copyright © 2016, Yale Recommended Centerline Security Inc., an ASSA ABLOY Group company. 36" (91 cm) From Floor.
  • Page 5 Installing Strike Plates 7-16 / 8-32 x 1" UNCWS Frame 1" Dia. x 1"Deep Frame Inside of Door 1" Dia. x 1/2"Deep Door Frame P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 6 Determining Handing The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand “LH”, Hinges Left. Left Hand Reverse "LHR", Hinges Left. Open Inward.
  • Page 7 Changing Handing (if necessary) 4" Left Hand to 4" Right Hand Shown 4-24 x 1/4" PPHMS DO NOT TAMPER WITH OR LOOSEN E-CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REMOVE COVER P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 8 Changing Handing (if necessary) continued P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 9 Lockset Handing Configurations For 5.5" For 5.5" For 4" For 4" 4" Right Hand 4" Left Hand Confirm LH is Confirm RH is visible thru LH hole visible thru RH hole as shown for as shown for left hand installation. right hand installation.
  • Page 10 Installing Fire Cup Inside of Door Fire Cup and a UL marked Latchbolt must be used to qualify for UL listing. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 11 Adjusting Deadbolt Latch default 2-3/8" position optional 2-3/4" position Pull Press P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 12 Installing Deadbolt Latch & Latchbolt 7-16 / 8-32 x 1" UNCWS Inside of Door Bolt must be in retracted (unlocked) position before installing. Ensure arrow stamped on deadbolt is UP. Spacer collar must be used for 1" edge bore. Collar can be removed for Choose latchbolt 3/4"...
  • Page 13 Installing Exterior Deadbolt M6x44 PPHMS for standard door thickness shown Confirm bolt is retracted (unlocked). Choose through bolt appropriate Inside of Door for your door thickness. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 14 Installing Lock Chassis 10-32 x 1-1/2" PPHMS Inside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 15 Securing Back Plate to Door #6-32 x 1/2" POHMS Inside of Door Drill two pilot holes Ø1/8" x 1/2" deep Two #6-32 x 1/2" POHMS screws must be used to qualify for UL listing. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 16 Testing Latchbolt Operation Outside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 17 Attaching the Cable Assembly Inside of Door Test that cables are securely connected. Avoid interference with movement of lock when routing cable. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 18 Installing Interior Lock Inside of Door Turn thumbturn to adjust tailpiece orientation. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 19 Installing Interior Lock continued 10-32 x 5/8" POHMS 6-32 x 1" PPHMS Inside of Door DO NOT LOOSEN THIS SCREW P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 20 Installing Interior Lever Inside of Door "SNAP" Inside of Door Pull lever to ensure it is secure. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 21 Testing Final Latchbolt Operation Inside of Door Outside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 22 Testing Final Deadbolt Operation Confirm deadbolt operates smoothly with no resistance. If resistance, re- check installation and confirm mounting screws have not been over-tightened. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 23 Installing Optional Smart Module DO NOT install Smart Module with batteries in unit. Damage may occur. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 24 Installing Batteries & Cover "Welcome to Yale Real Living." Tighten screw to replace cover. Bolt must be in retracted (unlocked) position before installing batteries. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 25 Handing the Lock AFTER installing batteries and cover or AFTER a factory reset, activate touchscreen and create Master PIN code. Lock will then automatically determine handing. See 1 of Programming Instructions for how to set master code. Congratulations, you've installed the Yale Assure Lock Interconnected Key Free Touchscreen (YRC256)! ®...
  • Page 26: Hardware Troubleshooting

    Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not extend and lock jam alarm occurs a. Confirm manual operation. b. Enter your Master PIN code. c. With the bolt retracted, press menu Option 3 for Advanced Lock Settings. d.
  • Page 27: Programming Instructions

    Programming Instructions Exterior Escutcheon Interior Escutcheon "P" Key (Return to Previous) Speaker Lockout Mode Low Battery Indicator Failsafe 9 volt Privacy Battery Connection Button (Use Alkaline battery) Lock Activation Master PIN Code must be created before any further programming. Max User Codes = 250 with Z-Wave Plus or Zigbee network module Max User Codes = 25 without network module or with iM1 network module Max User Codes = 12 with Bluetooth P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 28 Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the gear key to continue."...
  • Page 29 Creating User PIN Codes Master PIN code must be created first. *Max user codes = 250 with Z-Wave or Zigbee network module Max user codes = 25 without network module or with iM1 network module Max user codes = 12 with Bluetooth "Menu Mode, enter number, press the gear key...
  • Page 30: Code Chart

    Unlocking Door with PIN Code Enter PIN Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name PIN Code Master User User User User User User User User User User User...
  • Page 31: Resetting Lock To Factory Default

    Resetting Lock to Factory Default Interior Lock When resetting the lock, all user codes, including the Master PIN code*, are deleted. All (4" Shown) programming features are reset to original default settings (see below). Reset Button Access 1. Remove the battery cover and batteries. 2.
  • Page 32 Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on the screen.
  • Page 33: Feature Programming Through Menu Mode Using Master Pin Code

    Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
  • Page 34: Programming Troubleshooting

    Programming Troubleshooting Symptom Suggested Action • • • • • • • • • • • • • • • • • • Check or gear • • • • • • • • • P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
  • Page 35 Ÿ Consult the dealer or an experienced radio/TV technician for help. Ÿ Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user's authority to operate the equipment. Industry Canada: This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
  • Page 36 Yale Z-Wave Plus Smart Module ® ® ® Installation Guide Adding a Yale Z-Wave Plus Smart Module ® to your Assure Lock & Z-Wave System 1. Install the Yale Smart Module into the slot above the battery compartment IMPORTANT: The batteries must be removed before removing the Yale Smart Module: •...
  • Page 37 CAN ICES-3B/NMB-3B 24/7 Tech Support : 1-855-492-0505 • www.yalehome.com Yale® is a registered trademark of ASSA ABLOY Residential Group. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. © Copyright 2019. All rights reserved. Reproduction in whole or in part without the...
  • Page 38 Yale ZigBee Module ® ® ® Installation and Programming Instructions Installing the ZigBee Module ® IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover. • Remove batteries. • Remove and/or insert network module. •...
  • Page 39 Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.
  • Page 40 Yale iM1 Network Module ® ® Installation and Programming Instructions Installing the Yale iM1 Network Module IMPORTANT: the batteries must be removed prior to removing and/or inserting the network module: • Remove battery cover and batteries. • Remove and/or insert Network Module. •...
  • Page 41 Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale®, Yale Real Living® and Assure Lock® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. nexTouch™ is a trademark of Yale Security Inc., an ASSA ABLOY Group Company.