Z-Wave Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) Product ID: 0x0600 Product Type ID: 0x8002 – YRC226-ZW2/YRC246-ZW2/YRC256-ZW2 (Touch Screen Deadbolt) Supported Command Classes Command Class Z-Wave Plus Info Command Class Manufacturer Specific Command Class Security...
Notifications Table Alarm Alarm Reports Alarm Level Description type 0x00 Master code was changed at keypad Master Code changed. 0xFB Master code was changed over RF 0x70 0x(01-max User added User added. Alarm level = user slot number users) 0x(01-max User deleted 0x21 User was deleted.
Page 5
Power to RFM was restored, sent by RF module. The RF Module Power 0x82 0x00 lock doesn’t send any alarm to the RF module when Cycled power is cycled. Disabled user 0x(01-max 0x83 A disabled user pin code was entered at the keypad entered at keypad users) A valid user can be both a normal user and a Non-...
Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent mode on/off 1 1 byte Silent. Default is 2 or Low Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 10 to 180 seconds default is 30 seconds...
Page 7
Yale Z-Wave Plus Smart Module ® ® ® Installation Guide Please use this procedure only when network primary controller is missing or otherwise inoperable. Adding a Yale Z-Wave Plus Smart Module to your Assure Lock & Z-Wave System ® 1. Install the Yale Smart Module into the slot above the battery compartment IMPORTANT: The batteries must be removed before removing the Yale Smart Module: •...
Page 9
Yale Assure Lock ® ® Interconnected Key Free Touchscreen ® Installation and Programming Instructions (YRC256) Inside Outside of Door of Door 4" Shown - 5.5" Available Before you begin Smart Module DOWNLOAD (Optional) THE BILT APP for step-by-step installation instructions & to register your product Retrofitting or modifying this product may impact fire rating, safety features and warranty.
Page 13
Installing Strike Plates 7-16 / 8-32 x 1" UNCWS Frame 1" Dia. x 1"Deep Frame Inside of Door 1" Dia. x 1/2"Deep Door Frame P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 14
Determining Handing The hand of a door is determined from the secure side of the door. The term "secure" means the side from which you initially unlock and enter. Left Hand “LH”, Hinges Left. Left Hand Reverse "LHR", Hinges Left. Open Inward.
Page 15
Changing Handing (if necessary) 4" Left Hand to 4" Right Hand Shown 4-24 x 1/4" PPHMS DO NOT TAMPER WITH OR LOOSEN E-CLIP AND ITS ASSEMBLY DO NOT LOOSEN THESE 6 SCREWS OR REMOVE COVER P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 17
Lockset Handing Configurations For 5.5" For 5.5" For 4" For 4" 4" Right Hand 4" Left Hand Confirm LH is Confirm RH is visible thru LH hole visible thru RH hole as shown for as shown for left hand installation. right hand installation.
Page 18
Installing Fire Cup Inside of Door Fire Cup and a UL marked Latchbolt must be used to qualify for UL listing. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 19
Adjusting Deadbolt Latch default 2-3/8" position optional 2-3/4" position Pull Press P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 20
Installing Deadbolt Latch & Latchbolt 7-16 / 8-32 x 1" UNCWS Inside of Door Bolt must be in retracted (unlocked) position before installing. Ensure arrow stamped on deadbolt is UP. Spacer collar must be used for 1" edge bore. Collar can be removed for Choose latchbolt 3/4"...
Page 21
Installing Exterior Deadbolt M6x44 PPHMS for standard door thickness shown Confirm bolt is retracted (unlocked). Choose through bolt appropriate Inside of Door for your door thickness. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 22
Installing Lock Chassis 10-32 x 1-1/2" PPHMS Inside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 23
Securing Back Plate to Door #6-32 x 1/2" POHMS Inside of Door Drill two pilot holes Ø1/8" x 1/2" deep Two #6-32 x 1/2" POHMS screws must be used to qualify for UL listing. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 24
Testing Latchbolt Operation Outside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 25
Attaching the Cable Assembly Inside of Door Test that cables are securely connected. Avoid interference with movement of lock when routing cable. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 26
Installing Interior Lock Inside of Door Turn thumbturn to adjust tailpiece orientation. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 27
Installing Interior Lock continued 10-32 x 5/8" POHMS 6-32 x 1" PPHMS Inside of Door DO NOT LOOSEN THIS SCREW P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 28
Installing Interior Lever Inside of Door "SNAP" Inside of Door Pull lever to ensure it is secure. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 29
Testing Final Latchbolt Operation Inside of Door Outside of Door P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 30
Testing Final Deadbolt Operation Confirm deadbolt operates smoothly with no resistance. If resistance, re- check installation and confirm mounting screws have not been over-tightened. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 31
Installing Optional Smart Module DO NOT install Smart Module with batteries in unit. Damage may occur. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 32
Installing Batteries & Cover "Welcome to Yale Real Living." Tighten screw to replace cover. Bolt must be in retracted (unlocked) position before installing batteries. P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 33
Handing the Lock AFTER installing batteries and cover or AFTER a factory reset, activate touchscreen and create Master PIN code. Lock will then automatically determine handing. See 1 of Programming Instructions for how to set master code. Congratulations, you've installed the Yale Assure Lock Interconnected Key Free Touchscreen (YRC256)! ®...
Page 34
Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Bolt will not extend and lock jam alarm occurs a. Confirm manual operation. b. Enter your Master PIN code. c. With the bolt retracted, press menu Option 3 for Advanced Lock Settings. d.
Page 35
Programming Instructions Exterior Escutcheon Interior Escutcheon "P" Key (Return to Previous) Speaker Lockout Mode Low Battery Indicator Failsafe 9 volt Privacy Battery Connection Button (Use Alkaline battery) Lock Activation Master PIN Code must be created before any further programming. Max User Codes = 250 with Z-Wave Plus or Zigbee network module Max User Codes = 25 without network module or with iM1 network module Max User Codes = 12 with Bluetooth P/N YRL-EMICL-256-KFTSINSTL-FUL Rev A...
Page 36
Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the gear key to continue."...
Page 37
Creating User PIN Codes Master PIN code must be created first. *Max user codes = 250 with Z-Wave or Zigbee network module Max user codes = 25 without network module or with iM1 network module Max user codes = 12 with Bluetooth "Menu Mode, enter number, press the gear key...
Page 38
Unlocking Door with PIN Code Enter PIN Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name PIN Code Master User User User User User User User User User User User...
Page 39
Resetting Lock to Factory Default When resetting the lock, all user codes, Interior Lock including the Master PIN code*, are deleted. All (4" Shown) programming features are reset to original default settings (see below). Reset Button 1. Remove the battery cover and batteries. Access 2.
Page 40
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on the screen.
Page 41
Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3.
Page 43
Ÿ Consult the dealer or an experienced radio/TV technician for help. Ÿ Warning: Changes or modifications to this device, not expressly approved by ASSA ABLOY Residential Group could void the user's authority to operate the equipment. Industry Canada: This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Need help?
Do you have a question about the YRC226 and is the answer not in the manual?