A053 - Lathe Did Not Resume Its Production Cycle

LATHE DID NOT
RESUME ITS
PRODUCTION CYCLE!
POSSIBLE CAUSES:
-LATHE CLAMPING
DEVICE NOT CLOSED
-CLAMPING SIGNAL
MISSING (INTERFACE,
PLC INPUT A1)
Description:
The Safety Time For Part Feed Out Elapsed alarm occurs if the value set in INPUT OVERALL PART LENGTH is not reached within 1
minute after the bar feed is commanded to feed out.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm.
Make sure that value for the INPUT OVERALL PART LENGTH is correct.
Check for any mechanical obstruction that will not allow the bar feed to reach the feed out distance.
Contact LNS America, Inc. for further information.