A026 - Servo Amplifier Battery Is Too Low - LNS HYDROBAR SPRINT 555 Troubleshooting And Spare Parts Manual

Hide thumbs Also See for HYDROBAR SPRINT 555:
Table of Contents

Advertisement

Chapter 1: Alarms
1 - 1 7

A026 - Servo Amplifier Battery is Too Low

SERVO AMPLIFIER
BATTERY IS
TOO LOW!
-REPLACE THE BATTERY
A026
Description:
The Servo Amplifier Battery is too Low alarm occurs if the voltage of the battery drops below the rated power that the absolute
encoder inside the servo motor requires.
Solution:
Replace the battery inside the Servo amplifier (refer to the procedure in Chapter 4 of the Hydrobar Sprint 555 Instruction Manual).
Then, press the STOP key on the remote control station to clear the message and reset the alarm.