1 - 1 0
A009 - Bar Feeder Retracted
BAR FEEDER RETRACTED
OR NOT LOCKED IN ITS
WORKING POSITION!
SIGNAL SQ10 MISSING
SECURE BAR FEEDER
IN ITS WORKING
POSITION TO RESUME
OPERATIONS
Description:
The Bar Feeder Retracted alarm occurs whenever the PLC detects input (I2.1 – SQ10). The problem is generated when the bar
feeder is retracted for spindle liner changeover.
Solution:
Press the HELP key on the remote control station. Press the F4 key (Page Down icon) three times.
Case
Input
Remote Pendant
1
Bit 1 = 1
2
Bit 1 = 0
For case 1, after the solution has been completed, press the STOP key on the remote control station to clear the message and reset
the alarm.
HYDROBAR SPRINT 555
A009
MODULE 2
76543210
Put the bar feeder back in its working position and lock it in place.
10
MODULE 2
Alarm needs to be cleared. Press the STOP key on the remote
76543210
control station to clear the message and reset the alarm.
0
Chapter 1: Alarms
Solution