PREPARATION

PREPARATION
1.
BEFORE YOU START
**BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT**
**DO NOT INSTALL IF DAMAGED**
**RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED**
a.
Be sure you have all the content of your purchase and required tools for
this installation.
b.
Installation may take at least 1 to 2 hours from start to finish.
c.
Plan to use as few elbows or turns as possible for more efficient air flow.
d.
Collar size may need to be increased if utilizing a long duct run.
At least 12" of vertical duct is required before any turn.
e.
f.
Do not try to install this unit by yourself, SERIOUS INJURY MAY OCCUR.
g.
Hiring a certified installer and electrician is recommended.
2.
LOCATION
**THIS MODEL MAY NOT FIT ALL CEILING HEIGHTS**
a.
Determine the exact location where you want to install the range hood.
Distance between cooktop and range hood should be between 27"-33".
b.
c.
Range hood should be mounted at stated measurements to ensure
performance and lifespan of electrical components.
d.
Correctly measure the dimension needed to install the unit.
e.
Electrical outlet will be positioned at the top right base of the unit.
3.
HOOD
a.
Inspect for signs of defect or damage. (ie. scratches, dents, loose seams,
etc.)
b.
Before mounting, power up the unit to make sure it is working properly.
Use Fig. 1a and 1b on page 5 for measurements

INSTALLATION

1. WALL MOUNT INSTALLATION
a.
Make sure all preparation steps are completed.
b.
Determine your ceiling height to see if you need an extension.
i. Hood unit height = 12-3/16"
ii. Duct cover height = 14-1/4" (lower) + 13-11/16" (upper)
iii. Minimum height (duct cover only) = 15-3/8"
iv. Maximum height (duct cover only) = 27-3/8"
v. (OPTIONAL) Extension duct cover height = 46-7/8"
vi. Minimum height (lower duct cover with extension only) = 47-1/4"
vii. Maximum height (lower duct cover with extension only) = 60"
c.
Determine the location you want to install the range hood. (Fig. 2a)
d.
Prepare back wall frame with cross wood support.
e.
Mount the unit onto wall with mounting screws (not included)
f.
Adjust the duct cover mounting bracket to your desired height.
g.
Use a spirit level to ensure the balance of the hood is true.
(OPTIONAL) Use the conversion collar for 7" ducting.
h.
Connect a 6" or 7" ducting to the collar of the hood.
i.
j.
Connect the exhaust piping to the outlet of the unit. (Fig. 2b)
k.
Finish off by sealing the connection point with aluminum tape.
l.
Slide the duct cover into the unit and adjust its height. (Fig. 2c)
m. Secure it with the (6) duct cover screws provided. (Fig. 2d)
2. EXTENSION DUCT COVER INSTALLATION (OPTIONAL)
a.
Replace the original upper duct cover piece with the extension.
b.
Determine the desired height to mount the duct cover.
REPEAT "STEP F – M" from WALL MOUNT INSTALLATION section.
c.
INSTALLATION