Keysight E6640A/E6650A Rack Mount Kit This installation note contains procedures for installing the Rack Mount Kit for the Keysight E6640A/E6650A 18-slot PXIe Chassis in a standard EIA rack Installation Guide...
Page 3
Where to Find the Latest Information Documentation is updated periodically. For the latest information about these products, including instrument software upgrades, application information, and product information, browse to one of the following URLs, according to the name of your product: http://www.keysight.com/find/exm To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL: http://www.keysight.com/find/MyKeysight...
Keysight E6640A/E6650A Rack Mount Kit Installation Guide Rack Mount Kit Installation This installation note contains procedures for installing the Rack Mount Kit for the Keysight E6640A/E6650A 18-slot PXIe Chassis in a standard EIA rack. Parts List Description Part Number Quantity...
Rack Mount Kit Installation Installation Procedure 1. Refer to the figure below. Remove the side handles and handle covers from both sides of the M9018A PXIe chassis. Do not stand the chassis on its side; the side handles may cause the chassis to tip over.
Page 7
Rack Mount Kit Installation 3. Attach the rack flanges (p/n: E6640-00006 & E6640-00007) to the chassis using the M4.0 screws (p/n: 0515- 2043). Figure 2 Attaching handles and rack mount flanges to the E6640A/E6650A chassis Installation Guide...
Page 8
Rack Mount Kit Installation 4. Attach the leveling slides to the underside of the chassis using the M4.0 flat head screws (p/n: 0515-0896). Refer to the figure below. Figure 3 Attaching leveling slides to the E6640A/E6650A chassis Installation Guide...
Page 9
Rack Mount Kit Installation 5. Using the rack mount flanges as templates, position the flanges on the rack’s vertical columns where the chassis is to be mounted. Align the adapter holes over the “center” holes of the EIA rack units. Slide channel nuts over the rack holes to be used by the rack mount flanges.
Page 10
Rack Mount Kit Installation 6. Use the material from the Y1217A Rack Mount Rail Kit to position the rails on the rack's vertical columns where the chassis is to be mounted. Align the adapter holes over the “center” holes of the EIA rack units. INSTALL THE SUPPORT RAILS UPSIDE DOWN IN THE RACK! To provide adequate air flow to the ventilation holes on the sides of the chassis, you must install the rack slides upside down as illustrated in the next step.
Page 11
Rack Mount Kit Installation 10. Slide the E6640A/E6650A chassis into the rack until the rack mount front handle flanges are against the rack’s vertical columns. Secure the chassis to the rack using the dress screws (p/n: 0570-1577) provided with the rack flange kit.