TBOX BASIC ACS control panels are equipped with 5 homologated electromechanical thermostats, two temperature
gauges, a main power ON/OFF switch, a Summer/Winter selector, function indicators, a test button and a protective fuse.
Main control panel ON/OFF switch ( b )
This switch connects power to all controlled devices and
appliances.
b
A delayed action 6.3 A fuse is installed inside the control
panel upstream from this switch (see wiring diagram).
Summer/Winter selector (o/y)
Selects functioning mode:
- Summer (o domestic hot water only)
- Winter (y domestic hot water and central heating)
Boiler control thermostat (r)
The boiler control thermostat lets you adjust boiler tem-
perature between 60 and 82°C The recommended set-
ting is around 70°C.
Storage cylinder control thermostat (v)
The storage cylinder control thermostat lets you adjust
domestic hot water temperature between 0°C and 70°C
with priority logic. The recommended setting is around
50°C.