3�8 Connecting The Heat Pump To The; Power Supply - Calorex C-PAC+ CPT6 ALY Owners & Installation Manual

Swimming pool heat pumps
Table of Contents

Advertisement

3�8 CONNECTING THE HEAT PUMP TO THE POWER
SUPPLY
1
Undo e screws
Remove
two screws
Single phase
Terminals in Heat Pump Electrics enclosure
Power
terminals
terminals
L N
P1 P2
Cable clamp
Supply
cord
Fuse/MCB
RCD/
Circuit
Breaker
L N
Distribution box
Ear ed Power
Supply 230V 50Hz
1006905 ISSUE 2
ese
Li lower
panel away
Pump
Secure cables
using cable clamps
and feed
rough
cable entry points in
machine
Isolator which
disconnects all poles
fitted wi in 2m and in line
of sight of
e heat pump
2
The terminals for connecting
e heat pump to e power supply
are behind is panel.
Cable Entry point
Remove
ese
four screws and
remove cover
Three phase
Terminals in Heat Pump Electrics enclosure
Power
terminals
terminals
L1
L2
L3 N
P1 P2
Cable clamp
Supply
cord
Isolator which
disconnects all poles
fitted wi in 2m and in line
of sight of
Fuses/MCB
RCD/
Circuit
Breaker
L1
L3
L2
N
Distribution box
Ear ed Power
Supply 400V 50Hz
Two cable
entry points
Pump
Secure cables
using cable
clamps and feed
rough cable
entry points in
machine
e heat pump
17