Calorex Aquatherm DIGITAL LOGIC AT1000 Owner Operational Manual

Swimming pool & spa heat pumps black cabinet with digital controls only

Advertisement

Quick Links

SWIMMING POOL & SPA
SWIMMING POOL & SPA
OPERATIONAL MANUAL
DIGITAL
LOGIC™
Model AT1000 AT800 AT600 & AT400
"BLACK CABINET" with
NOTE: Installers should see separate installation manual !
WARNING: Specifications may change without notice.
V 2.5 © 2001 Aquatherm Heat Pumps a division of Calorex USA L.L.C
HEAT PUMPS
HEAT PUMPS
OWNERS
DIGITAL CONTROLS
ONLY
MEMBER
Pool
Heat
Pump
NATIONAL
Manufacturers
POOL & SPA
Association
INSTITUTE

Advertisement

Table of Contents
loading

Summary of Contents for Calorex Aquatherm DIGITAL LOGIC AT1000

  • Page 1 “BLACK CABINET” with ONLY NOTE: Installers should see separate installation manual ! MEMBER Pool Heat Pump NATIONAL Manufacturers POOL & SPA Association INSTITUTE WARNING: Specifications may change without notice. V 2.5 © 2001 Aquatherm Heat Pumps a division of Calorex USA L.L.C...
  • Page 2: Table Of Contents

    Important Information to Record Installer Name ______________________________________________________________ Installer Phone _________________________ Install Date ________________________ Model Number _________________________ Serial Number ______________________ a Division of Calorex USA L.L.C. 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com HEAT PUMPS...
  • Page 3: Unit Exterior Description

    Unit Description AIR DISCHARGE FAN THERMOSTAT WARNING: ROTATING BLADE KEEP CONTROLS HANDS & HAIR CLEAR! WARNING POOL/SPA POOL/SPA SELECT SWITCH DANGER FROM ELECTRICAL SHOCK & ROTATING FAN ! OFF/ON SHUT OFF ALL POWER SWITCH BEFORE SERVICING ! CAUTION: MORE THAN ONE LED READOUT DISCONNECTION MAY BE SERIAL...
  • Page 4 “Digital Logic” Digital Control Panel Information HEATER ON/OFF: To start the heater press this button and it’s green light will come on. To disable the heater press this button and its green light will go off. THERMOSTAT BUTTONS: Pressing the + button will raise the set temperature. Pressing the - button will lower the set temperature.
  • Page 5 GREEN POWER LIGHT: This light indicates that the heater has control power. WARNING: This is not a supply line power indicator and caution should be used since more than one power disconnection may be required to isolate the heater electrically. WARNING: If the optional Time Clock Override is installed, you must shut off the water pumps main power disconnect as well to eliminate all power to the heater.
  • Page 6: Operational Instructions

    Operational Instructions When heating the pool or spa you should check the following items as they are all critical to the proper operation of the heater. 1. WATER FLOW Make sure all pool filters and traps are clean since the unit requires a minimum water flow in order to operate properly.
  • Page 7: Time Delay Modes

    5. TIME DELAY MODE This heater is equipped with an internal compressor time delay to allow the refrigerant to settle during start-up or restart cycles. When the heater is started the fan will run but the compressor will not start until the 3 to 5 minute delay has passed. The green heating light will be on when the compressor is running.
  • Page 8 Heat Pump Maintenance & Precautions Air Flow & Access Clearances AIR COIL (on 3 Sides) BASE (CONCRETE OR PREFAB) 1. Make sure the unit has a firm base. The heat pump will produce condensation (water) while in operation. You will notice water coming from the bottom drain ports when the unit is running.
  • Page 9 Feeders, Chemicals & Water Balance This heat pump is equipped with the highest marine grade cupronickel alloy heat ex- changer that is designed to resist corrosion from normal pool water. The life and con- dition of the heat exchanger is directly related to the pool water chemical balance and chemical usage techniques.
  • Page 10: Owner Cleaning & Maintenance

    Freezing Condition Precautions In areas where extended freezing conditions exist, the heater must be plumbed as shown here (and the installation manual), so it can be winterized. Water left inside the heater will freeze and cause damage. This plumbing setup will allow the use of pressur- ized air to clear the heat exchanger of water in preparation for an extended freeze.
  • Page 11: Operational Sequence & Troubleshooting Flow Chart

    Operational Sequence & Troubleshooting Flow Chart for “Digital Logic” Digital Control Models 220V Power Water Pump To Heater Timer Activates Green Power Light Water Pump Starts Flowing Water Pressure Water Press. SW LF Readout SW Closes Stays Open Displayed on LED No Water Flow Thermostat To Heater or...
  • Page 12 The heater is designed to shut off in defrost mode when the air temperature drop below 45˚F to 50˚F. Specifications may change without notice. © 2001 Aquatherm Heat Pumps a division of Calorex USA L.L.C.