8�0 DATASHEET
MODEL
PERFORMANCE CONDITION: Air 24°C/Water 26°C/RH 80%
Heating capacity
Input current
COP
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
Input current
COP
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
Input current
COP
TECHNICAL SPECIFICATIONS
Operating air temperature
POWER SUPPLY
Rated input power
Rated input current .
Maximum input current
Rated RCD
Rated fuse aM / MCB type C
Sound pressure level at 10m
Recommended water flow rate
Water pressure drop
Pool water connections
GENERAL DATA
Net dimensions (w x d x h)
Packed dimensions (w x d x h)
Net weight
HERMETIC SYSTEM
Refrigerant charge
Minimum area requirement
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675. R410a - 2088.
The data is subject to modification without prior warning.
1006905 ISSUE 2
UNITS CPT6 ALY
CPT8 ALY
kW
7.51
8.92
A
5.5
6.1
6.31
6.45
kW
5.75
6.9
A
5.49
6.26
4.69
4.88
kW
6.89
7.46
A
7.3
8.6
4.26
3.67
°C
230V Single Phase 50Hz
kW
1.91
2.22
A
5.49
6.26
A
10.0
15.3
A
30mA
30mA
A
20
20
dB(A)
<28
<29
m
/h
3.3
4.1
3
m/kPA
0.50/4.93
0.76/7.52
Inches
mm
933x401x657
mm
960x408x793
kg
50
59
kg
R32 0.9
R32 1.0
6.9
8.5
m2
CPT12 ALY CPT15 ALY
13.46
16.9
9.5
12.1
6.63
6.31
10.83
14.1
9.42
12.36
5.21
5.13
10.53
11.5
12.8
16.8
3.75
3.2
-10°C to 43°C
3.23
2.67
9.42
12.1
18.3
25.3
30mA
30mA
32
40
<30
<30
6.3
7.2
1.13/11.07
1.68/16.55
1½" or 50mm Female
1130x490x709
1154x520x845
71
93
R32 1.5
R32 1.5
19.1
19.1
CPT20 BLY
23.1
12.3
5.01
19.7
13.3
4.1
15.0
10.36
2.98
400V Three Phase 50Hz
4.6
12.3
11.1
30mA
20
<32
9.0
2.80/27.5
1299x520x809
1324x530x925
117
R410a 2.8
Not applicable
25