18.Trouble  Shooting - Nakanishi E800Z Operation Manual

Table of Contents

Advertisement

Trouble Shooting
18 
Trouble
Check Points
Power Switch is on,  but 
power lamp does not 
light.
After pushing the Start 
button, nothing 
happens.  Auto Mode-
motor does not rotate 
with +24V DC on the 
Start line.
,
Can
t control speed form 
exernal signal.
Motor does not rotate.
,
Can
t Rotate in reverse.
,
Can
t control speed from 
external signal.
,
Can
t reset error.
Cause
No voltage in Power Source 
Line. Power Source Plug is 
disconnected or not 
connected firmly.
Blown Fuse.
Thermal Shutdown.
Error lamp is lit.  After 
resetting system, Error lamp 
is not lit with motor Off, but 
Error lamp lites again when 
motor is switched On.
Error lamp cannot be shut 
off.
Motor Speed Selection 
Switch is set to INT or 500
No voltage (+24V DC) on 
Start line.
No voltage (+24V DC) on 
DIR̲IN line.
No voltage on VR line.
EA Error.
EE Error.
Inspect/Corrective Action
Use an approved tester to test voltage at the 
power outlet. Consult with a Iicensed.electrician 
prior to any electrical work or checks. 
Insert Power Source Plug into outlet with firmly. 
Check the power cable connection at the 
control unit.
Refer to section 8 Change Fuse, check if fuse 
(250V-T3.15AL) is blown. Even if only one fuse 
is blown, both fuses need to be changed 
together.
Check the temperature of the bottom of unit. If 
the bottom of the unit is very hot the thermal 
protection system has shut off motor power.  
Let the unit sit for 20 minutes and restart the 
system.
If E1, E8 or EH Error Code is displayed correct 
the cause of the error and reset the system.
If E3, E4, E7, EA or EE Error code is displayed, 
check the related system and correct the cause 
of the error.  Reset the system.  If E4 is 
displayed wait 20 minutes before restarting the 
system.
Check the Motor Speed Selection Switch and 
set to EXT.
Check +24V DC power supply and connecting 
wires.
Check if +0-10V DC between Pin10 and Pin23 
on CN2.  If no voltage the problem is external to 
the NAKANISHI control unit.
EA Error cannot be reset by recycling the Start 
Switch.  Shut down the Start signal on CN2 and 
cycle the Power Switch OFF and ON.
Check shorting pin on CN1 if not using Emergency Stop 
System.  If using Emergency Stop System, check 
continuity of connections to machine
,
s safety systems.
22

Advertisement

Table of Contents
loading

Table of Contents