(3)SAFE A/B PIN No. 3, 4, 11, 12) 
・The Safety Relay will be ON or OFF depending on the state of the Emergency Stop Signal PINs 1  
 and 9. 
・When there is continuity between PIN 3(SAFE-1A) and PIN 11(SAFE-1B) or between PIN 4 (SAFE-
 2A) and PIN 12 (SAFE-2B) the motor is off.  If there is no continuity between these pairs of pins  
 then the system is operating normally. 
・If the Emergency Stop Signal is OFF (Open) the Safety Relay will be OFF(Open) and the motor  
 power will be interrupted and the motor will stop. 
・If the
a
contacts of the Safety Relay are welded together by an over load or short circuit the
,
b contacts
 separation is maintained with more than 0.5mm spacing by the relay
 mechanism 
 
 ①CN1 Connector  Rating-Relay Contact Rating 
    Current Rating                  
    Voltage Rating                    
 ②Relay Contact Rating  (At resistance load COSφ=1)   
    ・Max. Current                  
    ・Load Rating                   
    ・Max. Voltage                   
    ・Current Rating                     
 
(4)AUTO (AUTO MODE Signal ) (CN1: Pin5, Pin13) 
When Control Switch is set to AUTO MODE, Pins 5 and 13 are 
ON(Closed). 
When Control Switch is set to MANUAL MODE, Pins 5 and 13 are OFF 
(Fig.14)
(Opened).
(The max. rating of transistor is V
use at less than the maximum rating) 
 
(5)PWON (Control Unit Power Source Detector) (CN1: Pin6, Pin14) 
When the control unit's power source is connected and the Power 
Switch is ON, Output Transistor is ON (Closed). 
(Fig.15)
 (The max. rating of transistor is V
Pc=100mW. Please use at less than the maximum rating) 
 
(6)External Input/Output Connector CN1 Pin Arrangement 
CAUTION
! 
When the E800Z is shipped from the factory, a shorting pin is installed between pins 1 & 9.
If this pin is not installed the Safety Relay will be open and the power supply to the motor
will be interrupted. When Connector CN1 is not used, the shorting pin must be installed.
When Connector CN1 is being used the shorting pin should be removed and the
connections made according to the description above.
 
=50V, I
CEO
3A   AC・DC 
250VAC・DC 
6A 
AC250V・DC30V   6A 
AC250V DC125V 
6A 
=50mA, P
=100mW. Please 
C
C
=50V, Ic=50mA, 
CEO
(Fig.16)
CN1
Fig.16
Fig.13
Fig.14
Fig.15
Short circuit pin
,
s recoil     
Pin5 
(AUTO+) 
Pin13 
(AUTO-) 
Pin6 
(PWON+) 
Pin14 
(PWON-) 