Clearance to Combustibles

Appliance
Top ............................................................ 0" (0mm)
Bottom ....................................................... 0" (0mm)
Side ........................................................... 0" (0mm)
Back .......................................................... 0" (0mm)
Venting
Concentric sections of DV Vent ................... 1" (25mm)
Non-concentric sections of DV Vent
Sides and bottom .................................... 1" (25mm)
Top .......................................................... 2" (51mm)

Mantels

The height a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
Refer to Figures 4a and 4b and the Mantel Charts
below them for correct mounting heights and widths.
• The distances and reference points are not
affected by the fitting of a bay window front trim kit.
• Noncombustible mantels and legs may be
installed at any height and width around the
appliance.
• When using paint or lacquer to finish the mantel, it
must be heat-resistant to prevent discoloration.
V
W
X
Y
Z
A
B
C
D
E
Bottom of Door Trim
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate Ref. of Comb. Chamber
Depth
V
10" (254mm)
W
8" (203mm)
X
6" (152mm)
Y
4" (101mm)
Z
2" (51mm)
Fig. 4a Combustible mantel leg minimum installation.
6
Fireplace
Fireplace
Louvre Assembly
Top
Top of Combustion
Chamber
CFM146
Mantel from Top
A
19" (483mm)
B
17" (432mm)
C
15" (381mm)
D
13" (330mm)
E
11" (279mm)
Black
Surround
Face
Mantel
Mantel
Leg
Side of
Combustion Chamber
Mantel
Ref.
Leg Depth
F
10" (254mm)
G
8" (203mm)
H
6" (152mm)
I
4" (101mm)
J
2" (51mm)
Fig. 4b Combustible mantel leg minimum installation.

Hearth

Although a hearth is not mandatory, one is recom-
mended for aesthetic purposes. A noncombustible
hearth which projects out 12" (305mm) or more from
the front of the fireplace is recommended.
Cold Climate Installation Recommendation:
When installing this unit against a
noninsulated exterior wall or chase,
it is mandatory that the outer walls be
insulated to conform to applicable
insulation codes.
J
I
H
G
F
Leg
CFM164a
K
L
M
N
O
CFM170
Mantel Leg from Side
Ref.
of Comb. Opening
K
11 " (292mm)
L
9 " (241mm)
M
7 " (191mm)
N
5 " (140mm)
O
3 " (89mm)