Clearance to Combustibles

Appliance
Top Standoffs ............................................0" (0 mm)
Bottom .......................................................0" (0 mm)
Side Standoffs ...........................................0" (0 mm)
Back Standoffs ..........................................0" (0 mm)
Front ....................................................36" (914 mm)
Top of Unit to Ceiling ...........................36" (914 mm)
Venting
Horizontal Termination through-a-side wall:
Vertical Sections:
Sides ..............................................2¹⁄₂" (64 mm)
Horizontal Sections:
Top .................................................3¹⁄₂" (89 mm)
Bottom ...........................................1¹⁄₂" (38 mm)
Sides ..............................................2¹⁄₂" (64 mm)
Vertical Vent Application:
Sides .............................................1¹⁄₂" (38 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 4a and 4b, the following Mantel Charts.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
A
B
C
D
E
Noncombustible Finish
Material
(Such as Dura Rock)
Fireplace Front
CFM146c
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate Ref. of Comb. Chamber
Depth
V
10" (254 mm)
W
9" (229 mm)
X
8" (203 mm)
Y
7" (178 mm)
Z
6" (152 mm)
Fig. 4a Combustible mantel minimum installation.
20009145
Combustible
Framing and Fin-
ish Wall Above
V
Standoffs
May use combus-
W
tible facing mate-
rial in this area
X
Standoff
Y
Z
Top of Sheet
Metal
CFM146c
Mantel from Top
DVT44
mantal chart
A
10" (254 mm)
B
9" (229 mm)
C
8" (203 mm)
D
7" (178 mm)
E
6" (152 mm)
Mantel
Leg
CFM164b
CFM164b
Side of Fireplace
Mantel Leg Char
DVT44
4/9/03 djt
Noncombustible
Finish Material
Mantel
Ref.
Leg Depth
F
12" (305 mm)
CFM170
DV Builder Front
G
9" (229 mm)
View
H
6" (152 mm)
I
4" (102 mm)
J
3" (76 mm)
Fig. 4b Combustible mantel leg minimum installation.
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305 mm) or more from
the front of the fireplace. The hearth cannot exceed 1¹⁄₂"
(38mm) in height from bottom of fireplace for ease of
door accessibility. (Fig. 5)
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.
If a vapor barrier is used it can not come into
contact with fireplace.
Chateau™
J
I
H
G
F
K
L
M
N
O
CFM170a
Mantel Leg from Side
Ref.
of Comb. Opening
K
12" (305 mm)
L
9" (229 mm)
M
6" (152 mm)
N
4" (102 mm)
O
3" (76 mm)

Hearth

5