Optional Top Vent Application; Installing The Dvrt36Rmh In A Mobile Home - Vermont Castings DVRT36 Homeowner's Installation & Operating Manual

Vermont indoor gas fireplace operating manual
Table of Contents

Advertisement

Vermont Castings, Majestic Products DVRT36/ 39/ 43

Optional Top Vent Application

The DVRT appliance is shipped as a rear vent unit. If
the installation layout requires the unit to be a top vent
configuration the appliance can be converted by
following the steps below.
When removing and refitting the plates
and adapter, be sure the associated
gaskets are undamaged and refitted as
required.
1. Remove the ten (10) screws securing the outer
collar adapter to the fireplace body. (Fig. 11)
2. Set the collar aside, complete with the gasket.
Do not damage the gasket, as the adapter
and gasket must be refitted.
3. Remove the insulation material (exposed in Step 2)
from the top of the unit. (Fig. 12) This material can
be discarded. However, if the unit is converted back
to rear vent for any reason a new piece of insulation
material approved by Vermont Castings, Majestic
Products must be used for this purpose.
4. Remove the four (4) screws securing the flue cover
plate to the top of the intake box and remove the
cover and gasket. (Fig. 12)
5. Remove the four (4) screws securing the flue pipe
to the back of the intake box and remove the pipe
and gasket. (Fig. 12)
6. Secure the plate and gasket removed in Step 4 over
the flue opening in the back of the intake box.
Ensure the gasket is in place and undamaged.
7. Install the flue pipe and gasket removed in Step 5
over the flue opening in the top of the intake box.
(Fig. 13)
8. Refit the outer collar adapter and gasket to the unit
with the round collar on the top. Secure the adapter
with the ten (10) screws removed in Step 1.
When converting appliance to top vent,
ensure the insulation material referred to
in Step 3 is completely removed.
Outer Collar
Adapter
Flue
Pipe
Remove
Screws (5)
Fig. 11 Remove screws from outer collar adapter.
10
Rear View
Remove
Screws
(5)
FP1030
Insulation
Flue
Cover
Flue
Pipe
Remove Screws (4)
Fig. 12 Remove flue cover, flue pipe and insulation pad.
The insulation pad extends beyond the
opening in the top of the unit. Be sure to
remove all of the insulation material
before completing the conversion.
Flue Pipe
Replace
Screws
(4)
Fig. 13 Flue cover and flue pipe location.
After conversion to top vent
configuration, the 4" (102mm) flue pipe
should be concentric within the 7"
(175mm) outer collar.
Installing the DVRT36RMH
in a Mobile Home
NOTE: Refer to "For Use in Mobile Homes: Model
DVRT36RMH" on Pages 46 and 47.
Remove
Screws
(4)
FP1027
Replace
Screws
(4)
Flue Cover
FP1028
10002428

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvrt43Dvrt39

Table of Contents