1
[3] RELEASE FX Section
A
(1) Remove the three screws. (BPZ30P100FTC)
(2) Remove the RELEASE FX section.
(3) Remove the two screws. (BPZ30P100FTC)
(4) Remove the SPFX Assy.
(5) Remove the Tortion spring/PRS.
(6) Remove the Tortion spring/LVR.
(7) Remove the lever.
Screw tightening order
The other screws are random order.
B
A
C
Refer to "1.4 ABOUT THE CALIBRATION OF
RELEASE FX LEVER".
Reassembly of the RELASE FX Section
1 Move the lever of the Slide VR (VR7601)
on the SPFX Assy to the center.
2 Connect the FFC/7P.
3 Attach the Tortion spring/LVR and Tortion
spring/PRS.
D
6
Tortion spring/LVR
1
FFC/7P
Lever
(VR7601)
2
E
SPFX Assy
1
• Bottom view
6
Tortion spring/PRS
F
64
1
2
2
3
3
Tortion spring/PRS
2
3
5
Tortion spring/PRS
4 Attach the step 3 parts to the Control panel.
5 Tighten three screws. (BPZ30P100FTC)
6 Styling the Tortion spring/LVR and Tortion
spring/PRS.
Lever
(VR7601)
Tortion spring/LVR
Note: Be sure to insert the hook section of the
RMX-1000
3
4
6
1
×3
Tortion spring/LVR
SPFX Assy
4
2
Lever
7
Note: When attaching to the unit, be sure
to hold this part so that it will not turn.
5
×3
4
Lever
lever into the VR7601 lever.
4
3
×2