Pioneer RMX-1000 Service Manual page 51

Hide thumbs Also See for RMX-1000:
Table of Contents

Advertisement

5
8 Mode 8: "RBN" for confirmation of the X-PAD
• This mode is for confirming X-PAD values with the INPUT level indicator and the 7-segment indicator.
When this mode is entered, "rbn" is displayed for 1 second on the 7-segment indicator.
• The data item for a touched position on the X-PAD is expressed as a figure in the range of 0 to 127 and displayed on the
7-segment indicator.
The LEDs of the INPUT level indicator light according to the position touched on the X-PAD.
• The X-PAD consists of 5 sensors.
A touched sensor is indicated by the corresponding LED so that you can judge if it is functioning properly.
Part to be operated
X-PAD
X-PAD
X-PAD sensor 1
X-PAD sensor 2
X-PAD sensor 3
X-PAD sensor 4
X-PAD sensor 5
Part and indicators to be used for the operation
Position indication
5
6
Indicators to be lit
INPUT level indicator
7-segment indicator
X-PAD LED 1
X-PAD LED 2
X-PAD LED 3
X-PAD LED 4
X-PAD LED 5
Position indication
The LED corresponding to a touched sensor lights.
RMX-1000
6
7
Remarks
Right: Lights off
Left: Full Illuminate
Right: 0
Left: 127
7
8
A
B
C
D
E
F
51