Pioneer RMX-1000 Service Manual page 53

Hide thumbs Also See for RMX-1000:
Table of Contents

Advertisement

5
Muting Circuit Test Mode
This mode is for confirming that the muting circuit operates properly.
Muting is activated only while the HOLD button is held pressed.
After a muting circuit test is started, the audio inputs/outputs are enabled and audio volume control using the INPUT LEVEL
and OUTPUT LEVEL controls is also enabled.
If the GAIN switch (CONNECTION selector switch) is switched in this mode, muting-ON is locked for about 2 seconds to
prevent GAIN switching noise.
For a complaint that noise is generated during switching of the GAIN switch (CONNECTION selector switch), perform
checking in this mode.
Muting state
7-segment indication
Muting activated
ON
Muting canceled
OFF
SUB UCOM (K0R UCOM) Clock Test Mode
This mode is for confirming that the SUB UCOM (K0R UCOM) is operating in sync with an external clock.
To start a test, after entering this mode, press the HOLD button.
When the SUB UCOM (K0R UCOM) operates in sync with an external clock, it is considered to be normal.
If it does not, the SUB UCOM (K0R UCOM) may be in failure.
SUB UCOM (K0R UCOM) clock information indications
State of SUB UCOM
(K0R UCOM)
Normal
(in sync with an external clock)
Abnormal
(in sync with an internal clock)
5
6
LED
HOLD lit
No indication
7-segment indication
LED
OK
HOLD lit
NG
HOLD lit
6
7
RMX-1000
7
8
A
B
C
D
E
F
53
8

Hide quick links: