Calorex IPT 8 Series Owners & Installation Manual page 38

I-pac / i-pac+ inverter heat pumps
Table of Contents

Advertisement

OWNER/INSTALLATION MANUAL
MODEL
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
COP range
Average COP at 50% Speed
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
COP range
Average COP at 50% Speed
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
TECHNICAL SPECIFICATIONS
Operating air temperature
Water heating setting range
Water cooling setting range
Power supply
Rated input power
Rated input current
Maximum input current
Rated RCD type B
Rated Fuse aM / MCB type C
Sound pressure level at 10m
Recommended water flow rate
Pressure drop
Pool water connections
GENERAL DATA
Net dimensions (w x d x h)
Packed dimensions (w x d x h)
Net weight
HERMETIC SYSTEM
Refrigerant charge R32
Minimum area requirement
NOTES
Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.
38
UNITS
IPT16 BLY
kW
21.0
14.8-6.4
10.3
kW
14.5
7.1-4.6
6.3
kW
9.5
°C
kW
0.41-3.15
A
0.59-4.56
A
5.8
mA
30
A
10
dB(A)
20.4-33.7
m
/h
8.0-10.0
3
m/kPa
0.61/6.0
Inches
mm
954x429x755
mm
1040x445x655
kg
68
kg
1.2
m2
12.3
IPT22 BLY
27.5
15.0-6.8
10.3
18.0
7.5-4.6
6.3
11.9
-10°C to 43°C
18°C to 40°C
12°C to 30°C
400V Three Phase 50Hz
0.48-3.91
0.69-5.66
7
30
10
23.0-34.4
10.0-12.0
0.77/7.5
1½" or 50mm Female
1084x429x948
1130x445x985
93
2.0
34.0
IPT28 BLY
36.0
14.8-6.0
10.2
23.9
7.5-4.6
6.3
16.0
0.64-5.20
0.92-7.53
9.5
30
16
22.1-34.2
12.0-18.0
0.85/8.5
1154x539x948
1200x555x985
120
2.7
62.0