8�0 DATASHEETS

MODEL
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%

COP range

Average COP at 50% Speed

PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity (kW)
TECHNICAL SPECIFICATIONS
Operating air temperature
Water heating setting range
Water cooling setting range
POWER SUPPLY
Rated input current
Maximum input current
Rated RCD type F
Rated Fuse aM / MCB type C
Recommended water flow rate
Pressure drop
Pool water connections
GENERAL DATA
Net dimensions (w x d x h)
Packed dimensions (w x d x h)
Net weight
HERMETIC SYSTEM
Refrigerant charge R32
Minimum area requirement
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.
36
UNITS
IPT8 ALX
9.5
13.2-5.4
8.9
kW
7.0
6.9-4.2
6.3
3.9
°C
°C
°C
0.3-1.79
A
1.38-7.58
A
9.5
mA
30
A
16
19.6-31.5
m
/h
3.0-5.0
3
m/kPa
0.36/3.5
Inches
mm
864 x 359 x 648
mm
950 x 375 x 675
kg
47
kg
0.6
m2
3.1
IPT12 ALX
IPT16 ALX
13.0
20.0
13.5-5.6
13.5-5.7
9.7
9.3
9.5
13.5
7.0-4.0
7.0-4.2
6.1
6.3
5.2
7.4
-5°C to 43°C
18°C to 40°C
12°C to 30°C
230V Single Phase 50Hz
0.40-2.38
0.57-3.21
1.82-10.8
2.60-14.61
12.5
19.5
30
30
16
25
21.9-32.0
24.3-36.1
4.0-6.0
7.0-10.0
0.41/4.0
0.56/5.5
1½" or 50mm Female
864 x 359 x 648 954 x 359 x 748
950 x 375 x 675 1040 x 375 x 775
49
68
0.9
1.1
6.9
10.3
IPT22 ALX
25.0
13.8-5.8
9.6
17.0
7.2-4.0
6.4
9.4
0.69-4.25
3.16-19.32
20
30
25
24.9-36.7
10.0-12.0
0.77/7.5
1084 x 429 x 948
1130 x 445 x 985
90
2.0
34.0
1005494 ISSUE 3