2�4 FEATURES
• Stepless DC inverter compressor
• EEV Technology (Electronic Equalisation Valve)
• Quick reverse cycle defrosting with 4-way valve
• High-efficiency twisted titanium heat exchanger
• High pressure and low pressure protection
• Soft start and wide voltage application
• Stable inverter control system
2�5 OPERATING CONDITIONS AND RANGE
Air temperature operating range:
I-PAC (IPT X models): -5-43°C
I-PAC+ (IPT Y models): -10-43°C
Water temperature setting range:
Heating: 18°C-40°C
Cooling: 12°C-30°C
2�6 OPERATING MODES
The heat pump has two modes: Boost mode and
Whisper mode.
Mode
Boost mode
Whisper mode
10
Modes
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fastest heating
Heating capacity: 20% to 80% capacity
Sound level: 3dB(A) lower than Boost mode
Characteristics