9�0� DATASHEETS
MODEL
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
COP range
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
COP range
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity (kW)
TECHNICAL SPECIFICATIONS
Operating air temperature
Rated input power
Rated input current
Maximum input current
Rated RCD
Rated fuse/MCB type C
Sound level at 10m
Advised water flow rate
Pool water connections
Hermetic system
Refrigerant charge R32
Net dimensions (w x d x h)
Packed dimensions (w x d x h)
Net weight
NOTES:
Heat pump performance parameters are subject to change without notice. Always refer to the nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.
1005494 ISS 1
UNITS
IPT8 ALX
kW
9.5
13.2-5.4
kW
7.0
6.9-4.2
3.9
°C
kW
0.3-1.79
A
1.38-7.58
A
9.5
A
30
A
16
dB(A)
19.6-31.5
m
/h
3.0-5.0
3
Inches
kg
0.6
mm
864 x 359 x 648
mm
950 x 375 x 675
kg
47
IPT12 ALX
IPT16 ALX
13.0
20.0
13.5-5.6
13.5-5.7
9.5
13.5
7.0-4.0
7.0-4.2
5.2
7.4
-5°C to 43°C
0.40-2.38
0.57-3.21
1.82-10.8
2.60-14.61
12.5
19.5
30
30
25
25
21.9-32.0
24.3-36.1
4.0-6.0
7.0-10.0
1½" or 50mm Female
0.9
1.1
864 x 359 x 648 954 x 359 x 748 1084 x 429 x 948
950 x 375 x 675 1040 x 375 x 775 1130 x 445 x 985
49
68
IPT22 ALX
25.0
13.8-5.8
17.0
7.2-4.0
9.4
0.69-4.25
3.16-19.32
20
30
25
24.9-36.7
10.0-12.0
2.0
90
23