While removing the power canister, you might notice an increase in fan speed. The fan speed
returns to normal after you have replaced the power canister.
To install a power canister
1
Unpack the new power canister. Save all packing materials in case you need to return the faulty
power canister.
2
Pull the power canister levers toward you.
3
Use the levers as handles to place the canister into the chassis of the storage shelf.
4
Slide the canister all the way into the chassis.
5
Rotate the levers toward the center of the canister to lock it in place.
6
Be sure that the power switch on the replacement power canister is turned off.
7
Plug in the power cord.
8
Make sure that the power connector fits snugly into the canister receptacle.
9
Attach the plastic strain relief to the power cord.
10 Be sure that the other end of the power cord is attached to a 220VAC power source.
11 Use the power switch on the new canister to turn it on.
12 Check the green Input AC Power LED and the amber Power Service Action Required LED on
the new power canister.
13 If the Input AC Power LED is on, and the Power Service Action Required LED is off the
replacement procedure has been completed.
14 If the Input AC Power LED is off, or the Power Service Action Required LED is on, check that the
power canister is installed correctly. Reinstall the power canister if needed.
15 If the LEDs are still not correct, contact Veritas Support.