AHnet Protocol:

Using 5 bytes to communication:
BYTE 0 is the header and should always FA in HEX mode
BYTE 1 is the unit AHnet address to send the command. To send the command to all the devices, there are special AHnet
address used as broadcast. Please, refer to the user manual unit as there are different family broadcast addresses
BYTE 2 is the function to execute on the unit
BYTE 3 first value of the function
BYTE 4 second value of the function. In some functions this value is not used and should be "00"
Below, there is some AHnet commands used to control the different devices family. You will found more AHnet commands on
the particular user manual