14
First line, shows the model name of the device
Serial: Serial number of the unit
Ver: Firmware version
Address: Configure the AHnet Address to send the
command. Use address 0 to broadcast the com-
mand instruction
Dynamic2 Control: Send basic commands to Dy-
namic2 monitors family. Select the AHnet address
to send the command, and press the function to
send to AHnet RS422 BUS
Dynamic3 Control: Send basic commands to Dy-
namic3 monitors family. Select the AHnet address
to send the command, and press the function to
send to AHnet RS422 BUS
Dynamic talk Control: Send basic commands to
Dynamic talk microphone family. Select the AHnet
address to send the command, and press the func-
tion to send to AHnet RS422 BUS
IP Address: Shows the actual ERT IP address. Note
that if the DIP6 is active, the unit is configured with
the factory IP and this IP information should be
different
MASK: Shows the actual ERT MAK address
Gateway: Shows the actual ERT gateway address
Configuration PSW: Enter 4006 password to con-
figure the ERT IP address. Next page shows the ERT
network configuration